t/nvmept_trim: increase transfer size for some tests
[fio.git] / tools / hist / fio-histo-log-pctiles.py
1 #!/usr/bin/env python3
2
3 # module to parse fio histogram log files, not using pandas
4 # runs in python v2 or v3
5 # to get help with the CLI: $ python fio-histo-log-pctiles.py -h
6 # this can be run standalone as a script but is callable
7 # assumes all threads run for same time duration
8 # assumes all threads are doing the same thing for the entire run
9
10 # percentiles:
11 #  0 - min latency
12 #  50 - median
13 #  100 - max latency
14
15 # TO-DO: 
16 #   separate read and write stats for randrw mixed workload
17 #   report average latency if needed
18 #   prove that it works (partially done with unit tests)
19
20 # to run unit tests, set UNITTEST environment variable to anything
21 # if you do this, don't pass normal CLI parameters to it
22 # otherwise it runs the CLI
23
24 import sys, os, math, copy, time
25 from copy import deepcopy
26 import argparse
27 from functools import reduce
28
29 unittest2_imported = True
30 try:
31     import unittest2
32 except ImportError:
33     unittest2_imported = False
34
35 msec_per_sec = 1000
36 nsec_per_usec = 1000
37 direction_read = 0
38 direction_write = 1
39
40 class FioHistoLogExc(Exception):
41     pass
42
43 # if there is an error, print message, and exit with error status
44
45 def myabort(msg):
46     print('ERROR: ' + msg)
47     sys.exit(1)
48
49 # convert histogram log file into a list of
50 # (time_ms, direction, bsz, buckets) tuples where
51 # - time_ms is the time in msec at which the log record was written
52 # - direction is 0 (read) or 1 (write)
53 # - bsz is block size (not used)
54 # - buckets is a CSV list of counters that make up the histogram
55 # caller decides if the expected number of counters are present
56
57
58 def exception_suffix( record_num, pathname ):
59     return 'in histogram record %d file %s' % (record_num+1, pathname)
60
61 # log file parser raises FioHistoLogExc exceptions
62 # it returns histogram buckets in whatever unit fio uses
63 # inputs:
64 #  logfn: pathname to histogram log file
65 #  buckets_per_interval - how many histogram buckets to expect
66 #  log_hist_msec - if not None, expected time interval between histogram records
67
68 def parse_hist_file(logfn, buckets_per_interval, log_hist_msec):
69     previous_ts_ms_read = -1
70     previous_ts_ms_write = -1
71  
72     with open(logfn, 'r') as f:
73         records = [ l.strip() for l in f.readlines() ]
74     intervals = []
75     last_time_ms = -1
76     last_direction = -1
77     for k, r in enumerate(records):
78         if r == '':
79             continue
80         tokens = r.split(',')
81         try:
82             int_tokens = [ int(t) for t in tokens ]
83         except ValueError as e:
84             raise FioHistoLogExc('non-integer value %s' % exception_suffix(k+1, logfn))
85
86         neg_ints = list([tk for tk in int_tokens if tk < 0])
87         if len(neg_ints) > 0:
88             raise FioHistoLogExc('negative integer value %s' % exception_suffix(k+1, logfn))
89
90         if len(int_tokens) < 3:
91             raise FioHistoLogExc('too few numbers %s' % exception_suffix(k+1, logfn))
92
93         direction = int_tokens[1]
94         if direction != direction_read and direction != direction_write:
95             raise FioHistoLogExc('invalid I/O direction %s' % exception_suffix(k+1, logfn))
96
97         time_ms = int_tokens[0]
98         if direction == direction_read:
99             if time_ms < previous_ts_ms_read:
100                 raise FioHistoLogExc('read timestamp in column 1 decreased %s' % exception_suffix(k+1, logfn))
101             previous_ts_ms_read = time_ms
102         elif direction == direction_write:
103             if time_ms < previous_ts_ms_write:
104                 raise FioHistoLogExc('write timestamp in column 1 decreased %s' % exception_suffix(k+1, logfn))
105             previous_ts_ms_write = time_ms
106
107         bsz = int_tokens[2]
108         if bsz > (1 << 24):
109             raise FioHistoLogExc('block size too large %s' % exception_suffix(k+1, logfn))
110
111         buckets = int_tokens[3:]
112         if len(buckets) != buckets_per_interval:
113             raise FioHistoLogExc('%d buckets per interval but %d expected in %s' % 
114                     (len(buckets), buckets_per_interval, exception_suffix(k+1, logfn)))
115
116         # hack to filter out records with the same timestamp
117         # we should not have to do this if fio logs histogram records correctly
118
119         if time_ms == last_time_ms and direction == last_direction:
120             continue
121         last_time_ms = time_ms
122         last_direction = direction
123
124         intervals.append((time_ms, direction, bsz, buckets))
125     if len(intervals) == 0:
126         raise FioHistoLogExc('no records in %s' % logfn)
127     (first_timestamp, _, _, _) = intervals[0]
128     if first_timestamp < 1000000:
129         start_time = 0    # assume log_unix_epoch = 0
130     elif log_hist_msec != None:
131         start_time = first_timestamp - log_hist_msec
132     elif len(intervals) > 1:
133         (second_timestamp, _, _, _) = intervals[1]
134         start_time = first_timestamp - (second_timestamp - first_timestamp)
135     else:
136         raise FioHistoLogExc('no way to estimate test start time')
137     (end_timestamp, _, _, _) = intervals[-1]
138
139     return (intervals, start_time, end_timestamp)
140
141
142 # compute time range for each bucket index in histogram record
143 # see comments in https://github.com/axboe/fio/blob/master/stat.h
144 # for description of bucket groups and buckets
145 # fio v3 bucket ranges are in nanosec (since response times are measured in nanosec)
146 # but we convert fio v3 nanosecs to floating-point microseconds
147
148 def time_ranges(groups, counters_per_group, fio_version=3):
149     bucket_width = 1
150     bucket_base = 0
151     bucket_intervals = []
152     for g in range(0, groups):
153         for b in range(0, counters_per_group):
154             rmin = float(bucket_base)
155             rmax = rmin + bucket_width
156             if fio_version == 3:
157                 rmin /= nsec_per_usec
158                 rmax /= nsec_per_usec
159             bucket_intervals.append( [rmin, rmax] )
160             bucket_base += bucket_width
161         if g != 0:
162             bucket_width *= 2
163     return bucket_intervals
164
165
166 # compute number of time quantum intervals in the test
167
168 def get_time_intervals(time_quantum, min_timestamp_ms, max_timestamp_ms):
169     # round down to nearest second
170     max_timestamp = max_timestamp_ms // msec_per_sec
171     min_timestamp = min_timestamp_ms // msec_per_sec
172     # round up to nearest whole multiple of time_quantum
173     time_interval_count = ((max_timestamp - min_timestamp) + time_quantum) // time_quantum
174     end_time = min_timestamp + (time_interval_count * time_quantum)
175     return (end_time, time_interval_count)
176
177 # align raw histogram log data to time quantum so 
178 # we can then combine histograms from different threads with addition
179 # for randrw workload we count both reads and writes in same output bucket
180 # but we separate reads and writes for purposes of calculating
181 # end time for histogram record.
182 # this requires us to weight a raw histogram bucket by the 
183 # fraction of time quantum that the bucket overlaps the current
184 # time quantum interval
185 # for example, if we have a bucket with 515 samples for time interval
186 # [ 1010, 2014 ] msec since start of test, and time quantum is 1 sec, then
187 # for time quantum interval [ 1000, 2000 ] msec, the overlap is
188 # (2000 - 1010) / (2000 - 1000) = 0.99
189 # so the contribution of this bucket to this time quantum is
190 # 515 x 0.99 = 509.85
191
192 def align_histo_log(raw_histogram_log, time_quantum, bucket_count, min_timestamp_ms, max_timestamp_ms):
193
194     # slice up test time int intervals of time_quantum seconds
195
196     (end_time, time_interval_count) = get_time_intervals(time_quantum, min_timestamp_ms, max_timestamp_ms)
197     time_qtm_ms = time_quantum * msec_per_sec
198     end_time_ms = end_time * msec_per_sec
199     aligned_intervals = []
200     for j in range(0, time_interval_count):
201         aligned_intervals.append((
202             min_timestamp_ms + (j * time_qtm_ms),
203             [ 0.0 for j in range(0, bucket_count) ] ))
204
205     log_record_count = len(raw_histogram_log)
206     for k, record in enumerate(raw_histogram_log):
207
208         # find next record with same direction to get end-time
209         # have to avoid going past end of array
210         # for fio randrw workload, 
211         # we have read and write records on same time interval
212         # sometimes read and write records are in opposite order
213         # assertion checks that next read/write record 
214         # can be separated by at most 2 other records
215
216         (time_msec, direction, sz, interval_buckets) = record
217         if k+1 < log_record_count:
218             (time_msec_end, direction2, _, _) = raw_histogram_log[k+1]
219             if direction2 != direction:
220                 if k+2 < log_record_count:
221                     (time_msec_end, direction2, _, _) = raw_histogram_log[k+2]
222                     if direction2 != direction:
223                         if k+3 < log_record_count:
224                             (time_msec_end, direction2, _, _) = raw_histogram_log[k+3]
225                             assert direction2 == direction
226                         else:
227                             time_msec_end = end_time_ms
228                 else:
229                     time_msec_end = end_time_ms
230         else:
231             time_msec_end = end_time_ms
232
233         # calculate first quantum that overlaps this histogram record 
234
235         offset_from_min_ts = time_msec - min_timestamp_ms
236         qtm_start_ms = min_timestamp_ms + (offset_from_min_ts // time_qtm_ms) * time_qtm_ms
237         qtm_end_ms = min_timestamp_ms + ((offset_from_min_ts + time_qtm_ms) // time_qtm_ms) * time_qtm_ms
238         qtm_index = offset_from_min_ts // time_qtm_ms
239
240         # for each quantum that overlaps this histogram record's time interval
241
242         while qtm_start_ms < time_msec_end:  # while quantum overlaps record
243
244             # some histogram logs may be longer than others
245
246             if len(aligned_intervals) <= qtm_index:
247                 break
248
249             # calculate fraction of time that this quantum 
250             # overlaps histogram record's time interval
251             
252             overlap_start = max(qtm_start_ms, time_msec)
253             overlap_end = min(qtm_end_ms, time_msec_end)
254             weight = float(overlap_end - overlap_start)
255             weight /= (time_msec_end - time_msec)
256             (_,aligned_histogram) = aligned_intervals[qtm_index]
257             for bx, b in enumerate(interval_buckets):
258                 weighted_bucket = weight * b
259                 aligned_histogram[bx] += weighted_bucket
260
261             # advance to the next time quantum
262
263             qtm_start_ms += time_qtm_ms
264             qtm_end_ms += time_qtm_ms
265             qtm_index += 1
266
267     return aligned_intervals
268
269 # add histogram in "source" to histogram in "target"
270 # it is assumed that the 2 histograms are precisely time-aligned
271
272 def add_to_histo_from( target, source ):
273     for b in range(0, len(source)):
274         target[b] += source[b]
275
276
277 # calculate total samples in the histogram buckets
278
279 def get_samples(buckets):
280     return reduce( lambda x,y: x + y, buckets)
281
282
283 # compute percentiles
284 # inputs:
285 #   buckets: histogram bucket array 
286 #   wanted: list of floating-pt percentiles to calculate
287 #   time_ranges: [tmin,tmax) time interval for each bucket
288 # returns None if no I/O reported.
289 # otherwise we would be dividing by zero
290 # think of buckets as probability distribution function
291 # and this loop is integrating to get cumulative distribution function
292
293 def get_pctiles(buckets, wanted, time_ranges):
294
295     # get total of IO requests done
296     total_ios = 0
297     for io_count in buckets:
298         total_ios += io_count
299
300     # don't return percentiles if no I/O was done during interval
301     if total_ios == 0.0:
302         return None
303
304     pctile_count = len(wanted)
305
306     # results returned as dictionary keyed by percentile
307     pctile_result = {}
308
309     # index of next percentile in list
310     pctile_index = 0
311
312     # next percentile
313     next_pctile = wanted[pctile_index]
314
315     # no one is interested in percentiles bigger than this but not 100.0
316     # this prevents floating-point error from preventing loop exit
317     almost_100 = 99.9999
318
319     # pct is the percentile corresponding to 
320     # all I/O requests up through bucket b
321     pct = 0.0
322     total_so_far = 0
323     for b, io_count in enumerate(buckets):
324         if io_count == 0:
325             continue
326         total_so_far += io_count
327         # last_pct_lt is the percentile corresponding to 
328         # all I/O requests up to, but not including, bucket b
329         last_pct = pct
330         pct = 100.0 * float(total_so_far) / total_ios
331         # a single bucket could satisfy multiple pctiles
332         # so this must be a while loop
333         # for 100-percentile (max latency) case, no bucket exceeds it 
334         # so we must stop there.
335         while ((next_pctile == 100.0 and pct >= almost_100) or
336                (next_pctile < 100.0  and pct > next_pctile)):
337             # interpolate between min and max time for bucket time interval
338             # we keep the time_ranges access inside this loop, 
339             # even though it could be above the loop,
340             # because in many cases we will not be even entering 
341             # the loop so we optimize out these accesses
342             range_max_time = time_ranges[b][1]
343             range_min_time = time_ranges[b][0]
344             offset_frac = (next_pctile - last_pct)/(pct - last_pct)
345             interpolation = range_min_time + (offset_frac*(range_max_time - range_min_time))
346             pctile_result[next_pctile] = interpolation
347             pctile_index += 1
348             if pctile_index == pctile_count:
349                 break
350             next_pctile = wanted[pctile_index]
351         if pctile_index == pctile_count:
352             break
353     assert pctile_index == pctile_count
354     return pctile_result
355
356
357 # this is really the main program
358
359 def compute_percentiles_from_logs():
360     parser = argparse.ArgumentParser()
361     parser.add_argument("--fio-version", dest="fio_version", 
362         default="3", choices=[2,3], type=int, 
363         help="fio version (default=3)")
364     parser.add_argument("--bucket-groups", dest="bucket_groups", default="29", type=int, 
365         help="fio histogram bucket groups (default=29)")
366     parser.add_argument("--bucket-bits", dest="bucket_bits", 
367         default="6", type=int, 
368         help="fio histogram buckets-per-group bits (default=6 means 64 buckets/group)")
369     parser.add_argument("--percentiles", dest="pctiles_wanted", 
370         default=[ 0., 50., 95., 99., 100.], type=float, nargs='+',
371         help="fio histogram buckets-per-group bits (default=6 means 64 buckets/group)")
372     parser.add_argument("--time-quantum", dest="time_quantum", 
373         default="1", type=int,
374         help="time quantum in seconds (default=1)")
375     parser.add_argument("--log-hist-msec", dest="log_hist_msec", 
376         type=int, default=None,
377         help="log_hist_msec value in fio job file")
378     parser.add_argument("--output-unit", dest="output_unit", 
379         default="usec", type=str,
380         help="Latency percentile output unit: msec|usec|nsec (default usec)")
381     parser.add_argument("file_list", nargs='+', 
382         help='list of files, preceded by " -- " if necessary')
383     args = parser.parse_args()
384
385     # default changes based on fio version
386     if args.fio_version == 2:
387         args.bucket_groups = 19
388
389     # print parameters
390
391     print('fio version = %d' % args.fio_version)
392     print('bucket groups = %d' % args.bucket_groups)
393     print('bucket bits = %d' % args.bucket_bits)
394     print('time quantum = %d sec' % args.time_quantum)
395     print('percentiles = %s' % ','.join([ str(p) for p in args.pctiles_wanted ]))
396     buckets_per_group = 1 << args.bucket_bits
397     print('buckets per group = %d' % buckets_per_group)
398     buckets_per_interval = buckets_per_group * args.bucket_groups
399     print('buckets per interval = %d ' % buckets_per_interval)
400     bucket_index_range = range(0, buckets_per_interval)
401     if args.log_hist_msec != None:
402         print('log_hist_msec = %d' % args.log_hist_msec)
403     if args.time_quantum == 0:
404         print('ERROR: time-quantum must be a positive number of seconds')
405     print('output unit = ' + args.output_unit)
406     if args.output_unit == 'msec':
407         time_divisor = float(msec_per_sec)
408     elif args.output_unit == 'usec':
409         time_divisor = 1.0
410
411     # construct template for each histogram bucket array with buckets all zeroes
412     # we just copy this for each new histogram
413
414     zeroed_buckets = [ 0.0 for r in bucket_index_range ]
415
416     # calculate response time interval associated with each histogram bucket
417
418     bucket_times = time_ranges(args.bucket_groups, buckets_per_group, fio_version=args.fio_version)
419
420     # parse the histogram logs
421     # assumption: each bucket has a monotonically increasing time
422     # assumption: time ranges do not overlap for a single thread's records
423     # (exception: if randrw workload, then there is a read and a write 
424     # record for the same time interval)
425
426     test_start_time = 0
427     test_end_time = 1.0e18
428     hist_files = {}
429     for fn in args.file_list:
430         try:
431             (hist_files[fn], log_start_time, log_end_time)  = parse_hist_file(fn, buckets_per_interval, args.log_hist_msec)
432         except FioHistoLogExc as e:
433             myabort(str(e))
434         # we consider the test started when all threads have started logging
435         test_start_time = max(test_start_time, log_start_time)
436         # we consider the test over when one of the logs has ended
437         test_end_time = min(test_end_time, log_end_time)
438
439     if test_start_time >= test_end_time:
440         raise FioHistoLogExc('no time interval when all threads logs overlapped')
441     if test_start_time > 0:
442         print('all threads running as of unix epoch time %d = %s' % (
443                test_start_time/float(msec_per_sec), 
444                time.ctime(test_start_time/1000.0)))
445
446     (end_time, time_interval_count) = get_time_intervals(args.time_quantum, test_start_time, test_end_time)
447     all_threads_histograms = [ ((j*args.time_quantum*msec_per_sec), deepcopy(zeroed_buckets))
448                                for j in range(0, time_interval_count) ]
449
450     for logfn in hist_files.keys():
451         aligned_per_thread = align_histo_log(hist_files[logfn], 
452                                              args.time_quantum, 
453                                              buckets_per_interval, 
454                                              test_start_time,
455                                              test_end_time)
456         for t in range(0, time_interval_count):
457             (_, all_threads_histo_t) = all_threads_histograms[t]
458             (_, log_histo_t) = aligned_per_thread[t]
459             add_to_histo_from( all_threads_histo_t, log_histo_t )
460
461     # calculate percentiles across aggregate histogram for all threads
462     # print CSV header just like fiologparser_hist does
463
464     header = 'msec-since-start, samples, '
465     for p in args.pctiles_wanted:
466         if p == 0.:
467             next_pctile_header = 'min'
468         elif p == 100.:
469             next_pctile_header = 'max'
470         elif p == 50.:
471             next_pctile_header = 'median'
472         else:
473             next_pctile_header = '%3.1f' % p
474         header += '%s, ' % next_pctile_header
475
476     print('time (millisec), percentiles in increasing order with values in ' + args.output_unit)
477     print(header)
478
479     for (t_msec, all_threads_histo_t) in all_threads_histograms:
480         samples = get_samples(all_threads_histo_t)
481         record = '%8d, %8d, ' % (t_msec, samples)
482         pct = get_pctiles(all_threads_histo_t, args.pctiles_wanted, bucket_times)
483         if not pct:
484             for w in args.pctiles_wanted:
485                 record += ', '
486         else:
487             pct_keys = [ k for k in pct.keys() ]
488             pct_values = [ str(pct[wanted]/time_divisor) for wanted in sorted(pct_keys) ]
489             record += ', '.join(pct_values)
490         print(record)
491
492
493
494 #end of MAIN PROGRAM
495
496
497 ##### below are unit tests ##############
498
499 if unittest2_imported:
500   import tempfile, shutil
501   from os.path import join
502   should_not_get_here = False
503
504   class Test(unittest2.TestCase):
505     tempdir = None
506
507     # a little less typing please
508     def A(self, boolean_val):
509         self.assertTrue(boolean_val)
510
511     # initialize unit test environment
512
513     @classmethod
514     def setUpClass(cls):
515         d = tempfile.mkdtemp()
516         Test.tempdir = d
517
518     # remove anything left by unit test environment
519     # unless user sets UNITTEST_LEAVE_FILES environment variable
520
521     @classmethod
522     def tearDownClass(cls):
523         if not os.getenv("UNITTEST_LEAVE_FILES"):
524             shutil.rmtree(cls.tempdir)
525
526     def setUp(self):
527         self.fn = join(Test.tempdir, self.id())
528
529     def test_a_add_histos(self):
530         a = [ 1.0, 2.0 ]
531         b = [ 1.5, 2.5 ]
532         add_to_histo_from( a, b )
533         self.A(a == [2.5, 4.5])
534         self.A(b == [1.5, 2.5])
535
536     def test_b1_parse_log(self):
537         with open(self.fn, 'w') as f:
538             f.write('1234, 0, 4096, 1, 2, 3, 4\n')
539             f.write('5678,1,16384,5,6,7,8 \n')
540         (raw_histo_log, min_timestamp, max_timestamp) = parse_hist_file(self.fn, 4, None) # 4 buckets per interval
541         # if not log_unix_epoch=1, then min_timestamp will always be set to zero
542         self.A(len(raw_histo_log) == 2 and min_timestamp == 0 and max_timestamp == 5678)
543         (time_ms, direction, bsz, histo) = raw_histo_log[0]
544         self.A(time_ms == 1234 and direction == 0 and bsz == 4096 and histo == [ 1, 2, 3, 4 ])
545         (time_ms, direction, bsz, histo) = raw_histo_log[1]
546         self.A(time_ms == 5678 and direction == 1 and bsz == 16384 and histo == [ 5, 6, 7, 8 ])
547
548     def test_b2_parse_empty_log(self):
549         with open(self.fn, 'w') as f:
550             pass
551         try:
552             (raw_histo_log, _, _) = parse_hist_file(self.fn, 4, None)
553             self.A(should_not_get_here)
554         except FioHistoLogExc as e:
555             self.A(str(e).startswith('no records'))
556
557     def test_b3_parse_empty_records(self):
558         with open(self.fn, 'w') as f:
559             f.write('\n')
560             f.write('1234, 0, 4096, 1, 2, 3, 4\n')
561             f.write('5678,1,16384,5,6,7,8 \n')
562             f.write('\n')
563         (raw_histo_log, _, max_timestamp_ms) = parse_hist_file(self.fn, 4, None)
564         self.A(len(raw_histo_log) == 2 and max_timestamp_ms == 5678)
565         (time_ms, direction, bsz, histo) = raw_histo_log[0]
566         self.A(time_ms == 1234 and direction == 0 and bsz == 4096 and histo == [ 1, 2, 3, 4 ])
567         (time_ms, direction, bsz, histo) = raw_histo_log[1]
568         self.A(time_ms == 5678 and direction == 1 and bsz == 16384 and histo == [ 5, 6, 7, 8 ])
569
570     def test_b4_parse_non_int(self):
571         with open(self.fn, 'w') as f:
572             f.write('12, 0, 4096, 1a, 2, 3, 4\n')
573         try:
574             (raw_histo_log, _, _) = parse_hist_file(self.fn, 4, None)
575             self.A(False)
576         except FioHistoLogExc as e:
577             self.A(str(e).startswith('non-integer'))
578
579     def test_b5_parse_neg_int(self):
580         with open(self.fn, 'w') as f:
581             f.write('-12, 0, 4096, 1, 2, 3, 4\n')
582         try:
583             (raw_histo_log, _, _) = parse_hist_file(self.fn, 4, None)
584             self.A(False)
585         except FioHistoLogExc as e:
586             self.A(str(e).startswith('negative integer'))
587
588     def test_b6_parse_too_few_int(self):
589         with open(self.fn, 'w') as f:
590             f.write('0, 0\n')
591         try:
592             (raw_histo_log, _, _) = parse_hist_file(self.fn, 4, None)
593             self.A(False)
594         except FioHistoLogExc as e:
595             self.A(str(e).startswith('too few numbers'))
596
597     def test_b7_parse_invalid_direction(self):
598         with open(self.fn, 'w') as f:
599             f.write('100, 2, 4096, 1, 2, 3, 4\n')
600         try:
601             (raw_histo_log, _, _) = parse_hist_file(self.fn, 4, None)
602             self.A(False)
603         except FioHistoLogExc as e:
604             self.A(str(e).startswith('invalid I/O direction'))
605
606     def test_b8_parse_bsz_too_big(self):
607         with open(self.fn+'_good', 'w') as f:
608             f.write('100, 1, %d, 1, 2, 3, 4\n' % (1<<24))
609         (raw_histo_log, _, _) = parse_hist_file(self.fn+'_good', 4, None)
610         with open(self.fn+'_bad', 'w') as f:
611             f.write('100, 1, 20000000, 1, 2, 3, 4\n')
612         try:
613             (raw_histo_log, _, _) = parse_hist_file(self.fn+'_bad', 4, None)
614             self.A(False)
615         except FioHistoLogExc as e:
616             self.A(str(e).startswith('block size too large'))
617
618     def test_b9_parse_wrong_bucket_count(self):
619         with open(self.fn, 'w') as f:
620             f.write('100, 1, %d, 1, 2, 3, 4, 5\n' % (1<<24))
621         try:
622             (raw_histo_log, _, _) = parse_hist_file(self.fn, 4, None)
623             self.A(False)
624         except FioHistoLogExc as e:
625             self.A(str(e).__contains__('buckets per interval'))
626
627     def test_c1_time_ranges(self):
628         ranges = time_ranges(3, 2)  # fio_version defaults to 3
629         expected_ranges = [ # fio_version 3 is in nanoseconds
630                 [0.000, 0.001], [0.001, 0.002],   # first group
631                 [0.002, 0.003], [0.003, 0.004],   # second group same width
632                 [0.004, 0.006], [0.006, 0.008]]   # subsequent groups double width
633         self.A(ranges == expected_ranges)
634         ranges = time_ranges(3, 2, fio_version=3)
635         self.A(ranges == expected_ranges)
636         ranges = time_ranges(3, 2, fio_version=2)
637         expected_ranges_v2 = [ [ 1000.0 * min_or_max for min_or_max in time_range ] 
638                                for time_range in expected_ranges ]
639         self.A(ranges == expected_ranges_v2)
640         # see fio V3 stat.h for why 29 groups and 2^6 buckets/group
641         normal_ranges_v3 = time_ranges(29, 64)
642         # for v3, bucket time intervals are measured in nanoseconds
643         self.A(len(normal_ranges_v3) == 29 * 64 and normal_ranges_v3[-1][1] == 64*(1<<(29-1))/1000.0)
644         normal_ranges_v2 = time_ranges(19, 64, fio_version=2)
645         # for v2, bucket time intervals are measured in microseconds so we have fewer buckets
646         self.A(len(normal_ranges_v2) == 19 * 64 and normal_ranges_v2[-1][1] == 64*(1<<(19-1)))
647
648     def test_d1_align_histo_log_1_quantum(self):
649         with open(self.fn, 'w') as f:
650             f.write('100, 1, 4096, 1, 2, 3, 4')
651         (raw_histo_log, min_timestamp_ms, max_timestamp_ms) = parse_hist_file(self.fn, 4, None)
652         self.A(min_timestamp_ms == 0 and max_timestamp_ms == 100)
653         aligned_log = align_histo_log(raw_histo_log, 5, 4, min_timestamp_ms, max_timestamp_ms)
654         self.A(len(aligned_log) == 1)
655         (time_ms0, h) = aligned_log[0]
656         self.A(time_ms0 == 0 and h == [1., 2., 3., 4.])
657
658     # handle case with log_unix_epoch=1 timestamps, 1-second time quantum
659     # here both records will be separated into 2 aligned intervals
660
661     def test_d1a_align_2rec_histo_log_epoch_1_quantum_1sec(self):
662         with open(self.fn, 'w') as f:
663             f.write('1536504002123, 1, 4096, 1, 2, 3, 4\n')
664             f.write('1536504003123, 1, 4096, 4, 3, 2, 1\n')
665         (raw_histo_log, min_timestamp_ms, max_timestamp_ms) = parse_hist_file(self.fn, 4, None)
666         self.A(min_timestamp_ms == 1536504001123 and max_timestamp_ms == 1536504003123)
667         aligned_log = align_histo_log(raw_histo_log, 1, 4, min_timestamp_ms, max_timestamp_ms)
668         self.A(len(aligned_log) == 3)
669         (time_ms0, h) = aligned_log[0]
670         self.A(time_ms0 == 1536504001123 and h == [0., 0., 0., 0.])
671         (time_ms1, h) = aligned_log[1]
672         self.A(time_ms1 == 1536504002123 and h == [1., 2., 3., 4.])
673         (time_ms2, h) = aligned_log[2]
674         self.A(time_ms2 == 1536504003123 and h == [4., 3., 2., 1.])
675
676     # handle case with log_unix_epoch=1 timestamps, 5-second time quantum
677     # here both records will be merged into a single aligned time interval
678
679     def test_d1b_align_2rec_histo_log_epoch_1_quantum_5sec(self):
680         with open(self.fn, 'w') as f:
681             f.write('1536504002123, 1, 4096, 1, 2, 3, 4\n')
682             f.write('1536504003123, 1, 4096, 4, 3, 2, 1\n')
683         (raw_histo_log, min_timestamp_ms, max_timestamp_ms) = parse_hist_file(self.fn, 4, None)
684         self.A(min_timestamp_ms == 1536504001123 and max_timestamp_ms == 1536504003123)
685         aligned_log = align_histo_log(raw_histo_log, 5, 4, min_timestamp_ms, max_timestamp_ms)
686         self.A(len(aligned_log) == 1)
687         (time_ms0, h) = aligned_log[0]
688         self.A(time_ms0 == 1536504001123 and h == [5., 5., 5., 5.])
689
690     # we need this to compare 2 lists of floating point numbers for equality
691     # because of floating-point imprecision
692
693     def compare_2_floats(self, x, y):
694         if x == 0.0 or y == 0.0:
695             return (x+y) < 0.0000001
696         else:
697             return (math.fabs(x-y)/x) < 0.00001
698                 
699     def is_close(self, buckets, buckets_expected):
700         if len(buckets) != len(buckets_expected):
701             return False
702         compare_buckets = lambda k: self.compare_2_floats(buckets[k], buckets_expected[k])
703         indices_close = list(filter(compare_buckets, range(0, len(buckets))))
704         return len(indices_close) == len(buckets)
705
706     def test_d2_align_histo_log_2_quantum(self):
707         with open(self.fn, 'w') as f:
708             f.write('2000, 1, 4096, 1, 2, 3, 4\n')
709             f.write('7000, 1, 4096, 1, 2, 3, 4\n')
710         (raw_histo_log, min_timestamp_ms, max_timestamp_ms) = parse_hist_file(self.fn, 4, None)
711         self.A(min_timestamp_ms == 0 and max_timestamp_ms == 7000)
712         (_, _, _, raw_buckets1) = raw_histo_log[0]
713         (_, _, _, raw_buckets2) = raw_histo_log[1]
714         aligned_log = align_histo_log(raw_histo_log, 5, 4, min_timestamp_ms, max_timestamp_ms)
715         self.A(len(aligned_log) == 2)
716         (time_ms1, h1) = aligned_log[0]
717         (time_ms2, h2) = aligned_log[1]
718         # because first record is from time interval [2000, 7000]
719         # we weight it according
720         expect1 = [float(b) * 0.6 for b in raw_buckets1]
721         expect2 = [float(b) * 0.4 for b in raw_buckets1]
722         for e in range(0, len(expect2)):
723             expect2[e] += raw_buckets2[e]
724         self.A(time_ms1 == 0    and self.is_close(h1, expect1))
725         self.A(time_ms2 == 5000 and self.is_close(h2, expect2))
726
727     # what to expect if histogram buckets are all equal
728     def test_e1_get_pctiles_flat_histo(self):
729         with open(self.fn, 'w') as f:
730             buckets = [ 100 for j in range(0, 128) ]
731             f.write('9000, 1, 4096, %s\n' % ', '.join([str(b) for b in buckets]))
732         (raw_histo_log, min_timestamp_ms, max_timestamp_ms) = parse_hist_file(self.fn, 128, None)
733         self.A(min_timestamp_ms == 0 and max_timestamp_ms == 9000)
734         aligned_log = align_histo_log(raw_histo_log, 5, 128, min_timestamp_ms, max_timestamp_ms)
735         time_intervals = time_ranges(4, 32)
736         # since buckets are all equal, then median is halfway through time_intervals
737         # and max latency interval is at end of time_intervals
738         self.A(time_intervals[64][1] == 0.066 and time_intervals[127][1] == 0.256)
739         pctiles_wanted = [ 0, 50, 100 ]
740         pct_vs_time = []
741         for (time_ms, histo) in aligned_log:
742             pct_vs_time.append(get_pctiles(histo, pctiles_wanted, time_intervals))
743         self.A(pct_vs_time[0] == None)  # no I/O in this time interval
744         expected_pctiles = { 0:0.000, 50:0.064, 100:0.256 }
745         self.A(pct_vs_time[1] == expected_pctiles)
746
747     # what to expect if just the highest histogram bucket is used
748     def test_e2_get_pctiles_highest_pct(self):
749         fio_v3_bucket_count = 29 * 64
750         with open(self.fn, 'w') as f:
751             # make an empty fio v3 histogram
752             buckets = [ 0 for j in range(0, fio_v3_bucket_count) ]
753             # add one I/O request to last bucket
754             buckets[-1] = 1
755             f.write('9000, 1, 4096, %s\n' % ', '.join([str(b) for b in buckets]))
756         (raw_histo_log, min_timestamp_ms, max_timestamp_ms) = parse_hist_file(self.fn, fio_v3_bucket_count, None)
757         self.A(min_timestamp_ms == 0 and max_timestamp_ms == 9000)
758         aligned_log = align_histo_log(raw_histo_log, 5, fio_v3_bucket_count, min_timestamp_ms, max_timestamp_ms)
759         (time_ms, histo) = aligned_log[1]
760         time_intervals = time_ranges(29, 64)
761         expected_pctiles = { 100.0:(64*(1<<28))/1000.0 }
762         pct = get_pctiles( histo, [ 100.0 ], time_intervals )
763         self.A(pct == expected_pctiles)
764
765 # we are using this module as a standalone program
766
767 if __name__ == '__main__':
768     if os.getenv('UNITTEST'):
769         if unittest2_imported:
770             sys.exit(unittest2.main())
771         else:
772             raise Exception('you must install unittest2 module to run unit test')
773     else: