.. option:: flow=int
- Weight in token-based flow control. If this value is used, then there is a
- 'flow counter' which is used to regulate the proportion of activity between
- two or more jobs. Fio attempts to keep this flow counter near zero. The
- ``flow`` parameter stands for how much should be added or subtracted to the
- flow counter on each iteration of the main I/O loop. That is, if one job has
- ``flow=8`` and another job has ``flow=-1``, then there will be a roughly 1:8
- ratio in how much one runs vs the other.
+ Weight in token-based flow control. If this value is used, then fio
+ regulates the activity between two or more jobs sharing the same
+ flow_id. Fio attempts to keep each job activity proportional to other
+ jobs' activities in the same flow_id group, with respect to requested
+ weight per job. That is, if one job has `flow=3', another job has
+ `flow=2' and another with `flow=1`, then there will be a roughly 3:2:1
+ ratio in how much one runs vs the others.
.. option:: flow_sleep=int