.SS "Time related parameters"
.TP
.BI runtime \fR=\fPtime
-Tell fio to terminate processing after the specified period of time. It
-can be quite hard to determine for how long a specified job will run, so
-this parameter is handy to cap the total runtime to a given time. When
-the unit is omitted, the value is interpreted in seconds.
+Limit runtime. The test will run until it completes the configured I/O
+workload or until it has run for this specified amount of time, whichever
+occurs first. It can be quite hard to determine for how long a specified
+job will run, so this parameter is handy to cap the total runtime to a
+given time. When the unit is omitted, the value is interpreted in
+seconds.
.TP
.BI time_based
If set, fio will run for the duration of the \fBruntime\fR specified
OpenBSD and ZFS on Solaris don't support direct I/O. On Windows the synchronous
ioengines don't support direct I/O. Default: false.
.TP
-.BI atomic \fR=\fPbool
-If value is true, attempt to use atomic direct I/O. Atomic writes are
-guaranteed to be stable once acknowledged by the operating system. Only
-Linux supports O_ATOMIC right now.
-.TP
.BI buffered \fR=\fPbool
If value is true, use buffered I/O. This is the opposite of the
\fBdirect\fR option. Defaults to true.
before overwriting. The \fBtrimwrite\fR mode works well for this
constraint.
.TP
-.B pmemblk
-Read and write using filesystem DAX to a file on a filesystem
-mounted with DAX on a persistent memory device through the PMDK
-libpmemblk library.
-.TP
.B dev\-dax
Read and write using device DAX to a persistent memory device (e.g.,
/dev/dax0.0) through the PMDK libpmem library.
For direct I/O, requests will only succeed if cache invalidation isn't required,
file blocks are fully allocated and the disk request could be issued immediately.
.TP
+.BI (io_uring_cmd)fdp \fR=\fPbool
+Enable Flexible Data Placement mode for write commands.
+.TP
+.BI (io_uring_cmd)fdp_pli \fR=\fPstr
+Select which Placement ID Index/Indicies this job is allowed to use for writes.
+By default, the job will cycle through all available Placement IDs, so use this
+to isolate these identifiers to specific jobs. If you want fio to use placement
+identifier only at indices 0, 2 and 5 specify, you would set `fdp_pli=0,2,5`.
+.TP
.BI (cpuio)cpuload \fR=\fPint
Attempt to use the specified percentage of CPU cycles. This is a mandatory
option when using cpuio I/O engine.