.BI kb_base \fR=\fPint
The base unit for a kilobyte. The defacto base is 2^10, 1024. Storage
manufacturers like to use 10^3 or 1000 as a base ten unit instead, for obvious
-reasons. Allow values are 1024 or 1000, with 1024 being the default.
+reasons. Allowed values are 1024 or 1000, with 1024 being the default.
.TP
.BI unified_rw_reporting \fR=\fPbool
Fio normally reports statistics on a per data direction basis, meaning that
Specify a range of I/O block sizes. The issued I/O unit will always be a
multiple of the minimum size, unless \fBblocksize_unaligned\fR is set. Applies
to both reads and writes if only one range is given, but can be specified
-separately with a comma seperating the values. Example: bsrange=1k-4k,2k-8k.
+separately with a comma separating the values. Example: bsrange=1k-4k,2k-8k.
Also (see \fBblocksize\fR).
.TP
.BI bssplit \fR=\fPstr
.RS
.TP
.B random
-Choose a file at random
+Choose a file at random.
.TP
.B roundrobin
Round robin over open files (default).
+.TP
.B sequential
Do each file in the set sequentially.
.RE
.BI rate_iops \fR=\fPint
Cap the bandwidth to this number of IOPS. Basically the same as rate, just
specified independently of bandwidth. The same format as \fBrate\fR is used for
-read vs write seperation. If \fBblocksize\fR is a range, the smallest block
+read vs write separation. If \fBblocksize\fR is a range, the smallest block
size is used as the metric.
.TP
.BI rate_iops_min \fR=\fPint
If this rate of I/O is not met, the job will exit. The same format as \fBrate\fR
-is used for read vs write seperation.
+is used for read vs write separation.
.TP
.BI ratecycle \fR=\fPint
Average bandwidth for \fBrate\fR and \fBratemin\fR over this number of
be of the newly written data.
.RE
.TP
-.BI verify_sort \fR=\fPbool
+.BI verifysort \fR=\fPbool
If true, written verify blocks are sorted if \fBfio\fR deems it to be faster to
read them back in a sorted manner. Default: true.
.TP