write_bw_log=str If given, write an IOPS log of the jobs in this job
file. See write_bw_log.
+write_iops_log=str Same as write_bw_log, but writes IOPS. If no filename is
+ given with this option, the default filename of
+ "jobname_type.log" is used. Even if the filename is given,
+ fio will still append the type of log.
+
+log_avg_msec=int By default, fio will log an entry in the iops, latency,
+ or bw log for every IO that completes. When writing to the
+ disk log, that can quickly grow to a very large size. Setting
+ this option makes fio average the each log entry over the
+ specified period of time, reducing the resolution of the log.
+ Defaults to 0.
+
lockmem=int Pin down the specified amount of memory with mlock(2). Can
potentially be used instead of removing memory or booting
with less memory to simulate a smaller amount of memory.
uses. Fio will manually clear it from the CPU mask of other
jobs.
-continue_on_error=bool Normally fio will exit the job on the first observed
+continue_on_error=str Normally fio will exit the job on the first observed
failure. If this option is set, fio will continue the job when
there is a 'non-fatal error' (EIO or EILSEQ) until the runtime
is exceeded or the I/O size specified is completed. If this
given in the stats is the first error that was hit during the
run.
+ The allowed values are:
+
+ none Exit on any IO or verify errors.
+
+ read Continue on read errors, exit on all others.
+
+ write Continue on write errors, exit on all others.
+
+ io Continue on any IO error, exit on all others.
+
+ verify Continue on verify errors, exit on all others.
+
+ all Continue on all errors.
+
+ 0 Backward-compatible alias for 'none'.
+
+ 1 Backward-compatible alias for 'all'.
+
cgroup=str Add job to this control group. If it doesn't exist, it will
be created. The system must have a mounted cgroup blkio
mount point for this to work. If your system doesn't have it