Background a fio server, writing the pid to the given pid file.
.TP
.BI \-\-client \fR=\fPhost
-Instead of running the jobs locally, send and run them on the given host.
+Instead of running the jobs locally, send and run them on the given host or set of hosts. See client/server section.
.TP
.BI \-\-idle\-prof \fR=\fPoption
Report cpu idleness on a system or percpu basis (\fIoption\fP=system,percpu) or run unit work calibration only (\fIoption\fP=calibrate).
.B lfsr
Linear feedback shift register generator
.TP
+.B tausworthe64
+Strong 64-bit 2^258 cycle random number generator
+.TP
.RE
.P
Tausworthe is a strong random number generator, but it requires tracking on the
laid out or updated on disk, only that will be done. The actual job contents
are not executed.
.TP
+.BI allow_file_create \fR=\fPbool
+If true, fio is permitted to create files as part of its workload. This is
+the default behavior. If this option is false, then fio will error out if the
+files it needs to use don't already exist. Default: true.
+.TP
+.BI allow_mounted_write \fR=\fPbool
+If this isn't set, fio will abort jobs that are destructive (eg that write)
+to what appears to be a mounted device or partition. This should help catch
+creating inadvertently destructive tests, not realizing that the test will
+destroy data on the mounted file system. Default: false.
+.TP
.BI pre_read \fR=\fPbool
If this is given, files will be pre-read into memory before starting the given
IO operation. This will also clear the \fR \fBinvalidate\fR flag, since it is
Write extra information about each I/O (timestamp, block number, etc.). The
block number is verified. See \fBverify_pattern\fR as well.
.TP
+.B pattern
+Verify a strict pattern. Normally fio includes a header with some basic
+information and checksumming, but if this option is set, only the
+specific pattern set with \fBverify_pattern\fR is verified.
+.TP
.B null
Pretend to verify. Used for testing internals.
.RE
fio will fill 1/2/3/4 bytes of the buffer at the time(it can be either a
decimal or a hex number). The verify_pattern if larger than a 32-bit quantity
has to be a hex number that starts with either "0x" or "0X". Use with
-\fBverify\fP=meta.
+\fBverify\fP=meta or \fBverify\fP=pattern.
.TP
.BI verify_fatal \fR=\fPbool
If true, exit the job on the first observed verification failure. Default:
from. Setting \fBreplay_redirect\fR causes all IOPS to be replayed onto the
single specified device regardless of the device it was recorded from.
.TP
+.BI replay_align \fR=\fPint
+Force alignment of IO offsets and lengths in a trace to this power of 2 value.
+.TP
+.BI replay_scale \fR=\fPint
+Scale sector offsets down by this factor when replaying traces.
+.TP
+.BI per_job_logs \fR=\fPbool
+If set, this generates bw/clat/iops log with per file private filenames. If
+not set, jobs with identical names will share the log filename. Default: true.
+.TP
.BI write_bw_log \fR=\fPstr
If given, write a bandwidth log of the jobs in this job file. Can be used to
store data of the bandwidth of the jobs in their lifetime. The included
fio_generate_plots script uses gnuplot to turn these text files into nice
graphs. See \fBwrite_lat_log\fR for behaviour of given filename. For this
option, the postfix is _bw.x.log, where x is the index of the job (1..N,
-where N is the number of jobs)
+where N is the number of jobs). If \fBper_job_logs\fR is false, then the
+filename will not include the job index.
.TP
.BI write_lat_log \fR=\fPstr
Same as \fBwrite_bw_log\fR, but writes I/O completion latencies. If no
filename is given with this option, the default filename of
"jobname_type.x.log" is used, where x is the index of the job (1..N, where
N is the number of jobs). Even if the filename is given, fio will still
-append the type of log.
+append the type of log. If \fBper_job_logs\fR is false, then the filename will
+not include the job index.
.TP
.BI write_iops_log \fR=\fPstr
Same as \fBwrite_bw_log\fR, but writes IOPS. If no filename is given with this
option, the default filename of "jobname_type.x.log" is used, where x is the
index of the job (1..N, where N is the number of jobs). Even if the filename
-is given, fio will still append the type of log.
+is given, fio will still append the type of log. If \fBper_job_logs\fR is false,
+then the filename will not include the job index.
.TP
.BI log_avg_msec \fR=\fPint
By default, fio will log an entry in the iops, latency, or bw log for every
fio \-\-client=server \-\-remote-config /path/to/file.fio
-Then the fio serer will open this local (to the server) job file instead
+Then fio will open this local (to the server) job file instead
of being passed one from the client.
+
+If you have many servers (example: 100 VMs/containers), you can input a pathname
+of a file containing host IPs/names as the parameter value for the \-\-client option.
+For example, here is an example "host.list" file containing 2 hostnames:
+
+host1.your.dns.domain
+.br
+host2.your.dns.domain
+
+The fio command would then be:
+
+fio \-\-client=host.list <job file>
+
+In this mode, you cannot input server-specific parameters or job files, and all
+servers receive the same job file.
+
+In order to enable fio \-\-client runs utilizing a shared filesystem from multiple hosts,
+fio \-\-client now prepends the IP address of the server to the filename. For example,
+if fio is using directory /mnt/nfs/fio and is writing filename fileio.tmp,
+with a \-\-client hostfile
+containing two hostnames h1 and h2 with IP addresses 192.168.10.120 and 192.168.10.121, then
+fio will create two files:
+
+/mnt/nfs/fio/192.168.10.120.fileio.tmp
+.br
+/mnt/nfs/fio/192.168.10.121.fileio.tmp
+
.SH AUTHORS