Add support for --remote-config
[fio.git] / fio.1
diff --git a/fio.1 b/fio.1
index 62f40ea294d1695a926dcc420abce6f599c5dc2e..91c307482e1588cec985afb398ffc7f2fa074ee0 100644 (file)
--- a/fio.1
+++ b/fio.1
@@ -115,7 +115,29 @@ and there may be any number of global sections.  Specific job definitions
 may override any parameter set in global sections.
 .SH "JOB PARAMETERS"
 .SS Types
-Some parameters may take arguments of a specific type.  The types used are:
+Some parameters may take arguments of a specific type.
+Anywhere a numeric value is required, an arithmetic expression may be used,
+provided it is surrounded by parentheses. Supported operators are:
+.RS
+.RS
+.TP
+.B addition (+)
+.TP
+.B subtraction (-)
+.TP
+.B multiplication (*)
+.TP
+.B division (/)
+.TP
+.B modulus (%)
+.TP
+.B exponentiation (^)
+.RE
+.RE
+.P
+For time values in expressions, units are microseconds by default. This is
+different than for time values not in expressions (not enclosed in
+parentheses). The types used are:
 .TP
 .I str
 String: a sequence of alphanumeric characters.
@@ -182,8 +204,8 @@ set. On Windows, disk devices are accessed as \\.\PhysicalDrive0 for the first
 device, \\.\PhysicalDrive1 for the second etc. Note: Windows and FreeBSD
 prevent write access to areas of the disk containing in-use data
 (e.g. filesystems). If the wanted filename does need to include a colon, then
-escape that with a '\' character. For instance, if the filename is
-"/dev/dsk/foo@3,0:c", then you would use filename="/dev/dsk/foo@3,0\:c".
+escape that with a '\\' character. For instance, if the filename is
+"/dev/dsk/foo@3,0:c", then you would use filename="/dev/dsk/foo@3,0\\:c".
 .TP
 .BI filename_format \fR=\fPstr
 If sharing multiple files between jobs, it is usually necessary to have
@@ -478,7 +500,15 @@ size, fio can alternate random and zeroed data throughout the IO buffer.
 If set, fio will fill the IO buffers with this pattern. If not set, the contents
 of IO buffers is defined by the other options related to buffer contents. The
 setting can be any pattern of bytes, and can be prefixed with 0x for hex
-values.
+values. It may also be a string, where the string must then be wrapped with
+"".
+.TP
+.BI dedupe_percentage \fR=\fPint
+If set, fio will generate this percentage of identical buffers when writing.
+These buffers will be naturally dedupable. The contents of the buffers depend
+on what other buffer compression settings have been set. It's possible to have
+the individual buffers either fully compressible, or not at all. This option
+only controls the distribution of unique buffers.
 .TP
 .BI nrfiles \fR=\fPint
 Number of files to use for this job.  Default: 1.
@@ -612,6 +642,17 @@ options.
 Using Glusterfs libgfapi async interface to direct access to Glusterfs volumes without
 having to go through FUSE. This ioengine defines engine specific
 options.
+.TP
+.B libhdfs
+Read and write through Hadoop (HDFS).  The \fBfilename\fR option is used to
+specify host,port of the hdfs name-node to connect. This engine interprets
+offsets a little differently. In HDFS, files once created cannot be modified.
+So random writes are not possible. To imitate this, libhdfs engine expects
+bunch of small files to be created over HDFS, and engine will randomly pick a
+file out of those files based on the offset generated by fio backend. (see the
+example job file to create such files, use rw=write option). Please note, you
+might want to set necessary environment variables to work with hdfs/libhdfs
+properly.
 .RE
 .P
 .RE
@@ -657,17 +698,20 @@ Offset in the file to start I/O. Data before the offset will not be touched.
 .TP
 .BI offset_increment \fR=\fPint
 If this is provided, then the real offset becomes the
-offset + offset_increment * thread_number, where the thread number is a counter
-that starts at 0 and is incremented for each job. This option is useful if
-there are several jobs which are intended to operate on a file in parallel in
-disjoint segments, with even spacing between the starting points.
+offset + offset_increment * thread_number, where the thread number is a
+counter that starts at 0 and is incremented for each sub-job (i.e. when
+numjobs option is specified). This option is useful if there are several jobs
+which are intended to operate on a file in parallel disjoint segments, with
+even spacing between the starting points.
 .TP
 .BI number_ios \fR=\fPint
 Fio will normally perform IOs until it has exhausted the size of the region
 set by \fBsize\fR, or if it exhaust the allocated time (or hits an error
 condition). With this setting, the range/size can be set independently of
 the number of IOs to perform. When fio reaches this number, it will exit
-normally and report status.
+normally and report status. Note that this does not extend the amount
+of IO that will be done, it will only stop fio if this condition is met
+before other end-of-job criteria.
 .TP
 .BI fsync \fR=\fPint
 How many I/Os to perform before issuing an \fBfsync\fR\|(2) of dirty data.  If
@@ -1191,17 +1235,21 @@ If given, write a bandwidth log of the jobs in this job file. Can be used to
 store data of the bandwidth of the jobs in their lifetime. The included
 fio_generate_plots script uses gnuplot to turn these text files into nice
 graphs. See \fBwrite_lat_log\fR for behaviour of given filename. For this
-option, the postfix is _bw.log.
+option, the postfix is _bw.x.log, where x is the index of the job (1..N,
+where N is the number of jobs)
 .TP
 .BI write_lat_log \fR=\fPstr
 Same as \fBwrite_bw_log\fR, but writes I/O completion latencies.  If no
-filename is given with this option, the default filename of "jobname_type.log"
-is used. Even if the filename is given, fio will still append the type of log.
+filename is given with this option, the default filename of
+"jobname_type.x.log" is used, where x is the index of the job (1..N, where
+N is the number of jobs). Even if the filename is given, fio will still
+append the type of log.
 .TP
 .BI write_iops_log \fR=\fPstr
 Same as \fBwrite_bw_log\fR, but writes IOPS. If no filename is given with this
-option, the default filename of "jobname_type.log" is used. Even if the
-filename is given, fio will still append the type of log.
+option, the default filename of "jobname_type.x.log" is used, where x is the
+index of the job (1..N, where N is the number of jobs). Even if the filename
+is given, fio will still append the type of log.
 .TP
 .BI log_avg_msec \fR=\fPint
 By default, fio will log an entry in the iops, latency, or bw log for every
@@ -1210,6 +1258,27 @@ very large size. Setting this option makes fio average the each log entry
 over the specified period of time, reducing the resolution of the log.
 Defaults to 0.
 .TP
+.BI log_offset \fR=\fPbool
+If this is set, the iolog options will include the byte offset for the IO
+entry as well as the other data values.
+.TP
+.BI log_compression \fR=\fPint
+If this is set, fio will compress the IO logs as it goes, to keep the memory
+footprint lower. When a log reaches the specified size, that chunk is removed
+and compressed in the background. Given that IO logs are fairly highly
+compressible, this yields a nice memory savings for longer runs. The downside
+is that the compression will consume some background CPU cycles, so it may
+impact the run. This, however, is also true if the logging ends up consuming
+most of the system memory. So pick your poison. The IO logs are saved
+normally at the end of a run, by decompressing the chunks and storing them
+in the specified log file. This feature depends on the availability of zlib.
+.TP
+.BI log_store_compressed \fR=\fPbool
+If set, and \fBlog\fR_compression is also set, fio will store the log files in
+a compressed format. They can be decompressed with fio, using the
+\fB\-\-inflate-log\fR command line parameter. The files will be stored with a
+\fB\.fz\fR suffix.
+.TP
 .BI disable_lat \fR=\fPbool
 Disable measurements of total latency numbers. Useful only for cutting
 back the number of calls to \fBgettimeofday\fR\|(2), as that does impact performance at
@@ -1779,6 +1848,14 @@ does on the server side, to allow IP/hostname/socket and port strings.
 You can connect to multiple clients as well, to do that you could run:
 
 fio \-\-client=server2 \-\-client=server2 <job file(s)>
+
+If the job file is located on the fio server, then you can tell the server
+to load a local file as well. This is done by using \-\-remote-config:
+
+fio \-\-client=server \-\-remote-config /path/to/file.fio
+
+Then the fio serer will open this local (to the server) job file instead
+of being passed one from the client.
 .SH AUTHORS
 
 .B fio