From: Heiko Stuebner Date: Mon, 30 Sep 2024 21:04:24 +0000 (+0200) Subject: regulator: dt-bindings: vctrl-regulator: convert to YAML X-Git-Tag: v6.13-rc1~42^2~15 X-Git-Url: https://git.kernel.dk/?a=commitdiff_plain;h=4e9a2c91bff44336157eefd8d80b8ceb27918737;p=linux-block.git regulator: dt-bindings: vctrl-regulator: convert to YAML Convert the vctrl-regulator bindings to DT schema. This resolves a dtbs check warning for the rk3399-gru devices. Signed-off-by: Heiko Stuebner Reviewed-by: Conor Dooley Link: https://patch.msgid.link/20240930210424.1994047-1-heiko@sntech.de Signed-off-by: Mark Brown --- diff --git a/Documentation/devicetree/bindings/regulator/vctrl-regulator.yaml b/Documentation/devicetree/bindings/regulator/vctrl-regulator.yaml new file mode 100644 index 000000000000..6132b8e5b498 --- /dev/null +++ b/Documentation/devicetree/bindings/regulator/vctrl-regulator.yaml @@ -0,0 +1,80 @@ +# SPDX-License-Identifier: GPL-2.0-only OR BSD-2-Clause +%YAML 1.2 +--- +$id: http://devicetree.org/schemas/regulator/vctrl-regulator.yaml# +$schema: http://devicetree.org/meta-schemas/core.yaml# + +title: Voltage controlled regulators + +maintainers: + - Heiko Stuebner + +allOf: + - $ref: regulator.yaml# + +properties: + compatible: + const: vctrl-regulator + + ctrl-supply: + description: Regulator supplying the control voltage + + ctrl-voltage-range: + description: + Array of two integer values describing the range (min/max) of the + control voltage. The values specify the control voltage needed to + generate the corresponding regulator-min/max-microvolt output + voltage. + minItems: 2 + maxItems: 2 + $ref: /schemas/types.yaml#/definitions/uint32-array + + min-slew-down-rate: + description: + Describes how slowly the regulator voltage will decay down in the + worst case (lightest expected load). Specified in uV / us (like + main regulator ramp rate). This value is required when + ovp-threshold-percent is specified. + $ref: /schemas/types.yaml#/definitions/uint32 + + ovp-threshold-percent: + description: + Overvoltage protection (OVP) threshold of the regulator in percent. + Some regulators have an OVP circuitry which shuts down the regulator + when the actual output voltage deviates beyond a certain margin from + the expected value for a given control voltage. On larger voltage + decreases this can occur undesiredly since the output voltage does + not adjust immediately to changes in the control voltage. To avoid + this situation the vctrl driver breaks down larger voltage decreases + into multiple steps, where each step is within the OVP threshold. + minimum: 0 + maximum: 100 + +unevaluatedProperties: false + +dependencies: + ovp-threshold-percent: [ min-slew-down-rate ] + +required: + - compatible + - ctrl-supply + - ctrl-voltage-range + - regulator-min-microvolt + - regulator-max-microvolt + +examples: + - | + vctrl-reg { + compatible = "vctrl-regulator"; + regulator-name = "vctrl_reg"; + + ctrl-supply = <&ctrl_reg>; + ctrl-voltage-range = <200000 500000>; + + min-slew-down-rate = <225>; + ovp-threshold-percent = <16>; + + regulator-min-microvolt = <800000>; + regulator-max-microvolt = <1500000>; + }; +... diff --git a/Documentation/devicetree/bindings/regulator/vctrl.txt b/Documentation/devicetree/bindings/regulator/vctrl.txt deleted file mode 100644 index e940377cfd69..000000000000 --- a/Documentation/devicetree/bindings/regulator/vctrl.txt +++ /dev/null @@ -1,49 +0,0 @@ -Bindings for Voltage controlled regulators -========================================== - -Required properties: --------------------- -- compatible : must be "vctrl-regulator". -- regulator-min-microvolt : smallest voltage consumers may set -- regulator-max-microvolt : largest voltage consumers may set -- ctrl-supply : The regulator supplying the control voltage. -- ctrl-voltage-range : an array of two integer values describing the range - (min/max) of the control voltage. The values specify - the control voltage needed to generate the corresponding - regulator-min/max-microvolt output voltage. - -Optional properties: --------------------- -- ovp-threshold-percent : overvoltage protection (OVP) threshold of the - regulator in percent. Some regulators have an OVP - circuitry which shuts down the regulator when the - actual output voltage deviates beyond a certain - margin from the expected value for a given control - voltage. On larger voltage decreases this can occur - undesiredly since the output voltage does not adjust - immediately to changes in the control voltage. To - avoid this situation the vctrl driver breaks down - larger voltage decreases into multiple steps, where - each step is within the OVP threshold. -- min-slew-down-rate : Describes how slowly the regulator voltage will decay - down in the worst case (lightest expected load). - Specified in uV / us (like main regulator ramp rate). - This value is required when ovp-threshold-percent is - specified. - -Example: - - vctrl-reg { - compatible = "vctrl-regulator"; - regulator-name = "vctrl_reg"; - - ctrl-supply = <&ctrl_reg>; - - regulator-min-microvolt = <800000>; - regulator-max-microvolt = <1500000>; - - ctrl-voltage-range = <200000 500000>; - - min-slew-down-rate = <225>; - ovp-threshold-percent = <16>; - };