Typically, the r0 (calibration data) and temperature were measured in the factory.
This information is written into the non-volatile area
where keeps data whether factory reset or OS update.
Signed-off-by: Shuming Fan <shumingf@realtek.com>
Link: https://lore.kernel.org/r/20191016115617.23213-1-shumingf@realtek.com
Signed-off-by: Mark Brown <broonie@kernel.org>
| 1 | 1 | 0x3b |
-------------------------------------
+Optional properties:
+
+- realtek,temperature_calib
+ u32. The temperature was measured while doing the calibration. Units: Celsius degree
+
+- realtek,r0_calib
+ u32. This is r0 calibration data which was measured in factory mode.
+
Pins on the device (for linking into audio routes) for RT1011:
* SPO
rt1011: codec@38 {
compatible = "realtek,rt1011";
reg = <0x38>;
+ realtek,temperature_calib = <25>;
+ realtek,r0_calib = <0x224050>;
};