if (!nr)
return 0;
- if (td_random(td))
- o->ddir_seq_nr = atoi(nr);
- else {
+ if (td_random(td)) {
+ long long val;
+
+ if (str_to_decimal(nr, &val, 1, o, 0, 0)) {
+ log_err("fio: randrw postfix parsing failed\n");
+ free(nr);
+ return 1;
+ }
+ if ((val <= 0) || (val > UINT_MAX)) {
+ log_err("fio: randrw postfix parsing out of range\n");
+ free(nr);
+ return 1;
+ }
+ o->ddir_seq_nr = (unsigned int) val;
+ } else {
long long val;
if (str_to_decimal(nr, &val, 1, o, 0, 0)) {
.help = "Install libz-dev(el) to get compression support",
},
#endif
- {
- .name = "log_unix_epoch",
- .lname = "Log epoch unix",
- .type = FIO_OPT_BOOL,
- .off1 = offsetof(struct thread_options, log_unix_epoch),
- .help = "Use Unix time in log files",
- .category = FIO_OPT_C_LOG,
- .group = FIO_OPT_G_INVALID,
- },
{
.name = "log_alternate_epoch",
+ .alias = "log_unix_epoch",
.lname = "Log epoch alternate",
.type = FIO_OPT_BOOL,
.off1 = offsetof(struct thread_options, log_alternate_epoch),
.lname = "Log alternate epoch clock_id",
.type = FIO_OPT_INT,
.off1 = offsetof(struct thread_options, log_alternate_epoch_clock_id),
- .help = "If log_alternate_epoch or log_unix_epoch is true, this option specifies the clock_id from clock_gettime whose epoch should be used. If neither of those is true, this option has no effect. Default value is 0, or CLOCK_REALTIME",
+ .help = "If log_alternate_epoch is true, this option specifies the clock_id from clock_gettime whose epoch should be used. If log_alternate_epoch is false, this option has no effect. Default value is 0, or CLOCK_REALTIME",
.category = FIO_OPT_C_LOG,
.group = FIO_OPT_G_INVALID,
},
.category = FIO_OPT_C_GENERAL,
.group = FIO_OPT_G_CLOCK,
},
+ {
+ .name = "job_start_clock_id",
+ .lname = "Job start clock_id",
+ .type = FIO_OPT_INT,
+ .off1 = offsetof(struct thread_options, job_start_clock_id),
+ .help = "The clock_id passed to the call to clock_gettime used to record job_start in the json output format. Default is 0, or CLOCK_REALTIME",
+ .verify = gtod_cpu_verify,
+ .category = FIO_OPT_C_GENERAL,
+ .group = FIO_OPT_G_CLOCK,
+ },
{
.name = "unified_rw_reporting",
.lname = "Unified RW Reporting",