rv = func(client, page, reg);
if (rv >= 0 && !(data->flags & PMBUS_SKIP_STATUS_CHECK))
rv = pmbus_check_status_cml(client);
+ if (rv < 0 && (data->flags & PMBUS_READ_STATUS_AFTER_FAILED_CHECK))
+ data->read_status(client, -1);
pmbus_clear_fault_page(client, -1);
return rv >= 0;
}
*/
#define PMBUS_NO_CAPABILITY BIT(2)
+/*
+ * PMBUS_READ_STATUS_AFTER_FAILED_CHECK
+ *
+ * Some PMBus chips end up in an undefined state when trying to read an
+ * unsupported register. For such chips, it is necessary to reset the
+ * chip pmbus controller to a known state after a failed register check.
+ * This can be done by reading a known register. By setting this flag the
+ * driver will try to read the STATUS register after each failed
+ * register check. This read may fail, but it will put the chip in a
+ * known state.
+ */
+#define PMBUS_READ_STATUS_AFTER_FAILED_CHECK BIT(3)
+
struct pmbus_platform_data {
u32 flags; /* Device specific flags */