.. option:: steadystate_duration=time, ss_dur=time
- A rolling window of this duration will be used to judge whether steady state
- has been reached. Data will be collected every ss_check_interval.
- The default is 0 which disables steady state detection. When the unit is omitted,
- the value is interpreted in seconds.
+ A rolling window of this duration will be used to judge whether steady
+ state has been reached. Data will be collected every
+ :option:`ss_interval`. The default is 0 which disables steady state
+ detection. When the unit is omitted, the value is interpreted in
+ seconds.
.. option:: steadystate_ramp_time=time, ss_ramp=time
.. option:: steadystate_check_interval=time, ss_interval=time
- The values during the rolling window will be collected with a period
- of this value. If ss_interval is 30s and ss_dur is 300s, 10 measurements will
- be taken. Default is 1s but that might not converge, especially for
- slower cards, so set this accordingly. When the unit is omitted,
- the value is interpreted in seconds.
+ The values during the rolling window will be collected with a period of
+ this value. If :option:`ss_interval` is 30s and :option:`ss_dur` is
+ 300s, 10 measurements will be taken. Default is 1s but that might not
+ converge, especially for slower devices, so set this accordingly. When
+ the unit is omitted, the value is interpreted in seconds.
Measurements and reporting
.TP
.BI steadystate_duration \fR=\fPtime "\fR,\fP ss_dur" \fR=\fPtime
A rolling window of this duration will be used to judge whether steady state
-has been reached. Data will be collected once per second. The default is 0
-which disables steady state detection. When the unit is omitted, the
-value is interpreted in seconds.
+has been reached. Data will be collected every \fBss_interval\fR. The default
+is 0 which disables steady state detection. When the unit is omitted, the value
+is interpreted in seconds.
.TP
.BI steadystate_ramp_time \fR=\fPtime "\fR,\fP ss_ramp" \fR=\fPtime
Allow the job to run for the specified duration before beginning data
.TP
.BI steadystate_check_interval \fR=\fPtime "\fR,\fP ss_interval" \fR=\fPtime
The values suring the rolling window will be collected with a period of this
-value. Default is 1s but that might not converge, especially for slower cards,
-so set this accordingly. When the unit is omitted, the value is interpreted
-in seconds.
+value. If \fBss_interval\fR is 30s and \fBss_dur\fR is 300s, 10 measurements
+will be taken. Default is 1s but that might not converge, especially for slower
+devices, so set this accordingly. When the unit is omitted, the value is
+interpreted in seconds.
.SS "Measurements and reporting"
.TP
.BI per_job_logs \fR=\fPbool