If the pipeline setup fails at the first widget/pipeline then we will have
no spipe stored under the pipeline_list->pipelines, the
pipeline_list->count is 0.
If this is the case we would have a NULL pointer dereference if the
execution is allowed to proceed.
Check for this condition along with the pipeline_list->pipelines check
Signed-off-by: Peter Ujfalusi <peter.ujfalusi@linux.intel.com>
Reviewed-by: Pierre-Louis Bossart <pierre-louis.bossart@linux.intel.com>
Reviewed-by: Ranjani Sridharan <ranjani.sridharan@linux.intel.com>
Link: https://lore.kernel.org/r/20230127120031.10709-19-peter.ujfalusi@linux.intel.com
Signed-off-by: Mark Brown <broonie@kernel.org>
pipeline_list = &spcm->stream[substream->stream].pipeline_list;
/* nothing to trigger if the list is empty */
- if (!pipeline_list->pipelines)
+ if (!pipeline_list->pipelines || !pipeline_list->count)
return 0;
/* allocate memory for the pipeline data */