ext4: update the comment about mb_optimize_scan
authorZizhi Wo <wozizhi@huawei.com>
Mon, 24 Feb 2025 01:20:05 +0000 (09:20 +0800)
committerTheodore Ts'o <tytso@mit.edu>
Tue, 18 Mar 2025 04:15:25 +0000 (00:15 -0400)
Commit 196e402adf2e ("ext4: improve cr 0 / cr 1 group scanning") introduces
the sysfs control interface "mb_max_linear_groups" to address the problem
that rotational devices performance degrades when the "mb_optimize_scan"
feature is enabled, which may result in distant block group allocation.

However, the name of the interface was incorrect in the comment to the
ext4/mballoc.c file, and this patch fixes it, without further changes.

Signed-off-by: Zizhi Wo <wozizhi@huawei.com>
Reviewed-by: Baokun Li <libaokun1@huawei.com>
Reviewed-by: Ojaswin Mujoo <ojaswin@linux.ibm.com>
Reviewed-by: Zhang Yi <yi.zhang@huawei.com>
Link: https://patch.msgid.link/20250224012005.689549-1-wozizhi@huawei.com
Signed-off-by: Theodore Ts'o <tytso@mit.edu>
fs/ext4/mballoc.c

index a67c52063a422460b509795230d238e800a0fae9..0d523e9fb3d52952d896e1b0f685928540aceb50 100644 (file)
  * /sys/fs/ext4/<partition>/mb_min_to_scan
  * /sys/fs/ext4/<partition>/mb_max_to_scan
  * /sys/fs/ext4/<partition>/mb_order2_req
- * /sys/fs/ext4/<partition>/mb_linear_limit
+ * /sys/fs/ext4/<partition>/mb_max_linear_groups
  *
  * The regular allocator uses buddy scan only if the request len is power of
  * 2 blocks and the order of allocation is >= sbi->s_mb_order2_reqs. The
  * get traversed linearly. That may result in subsequent allocations being not
  * close to each other. And so, the underlying device may get filled up in a
  * non-linear fashion. While that may not matter on non-rotational devices, for
- * rotational devices that may result in higher seek times. "mb_linear_limit"
+ * rotational devices that may result in higher seek times. "mb_max_linear_groups"
  * tells mballoc how many groups mballoc should search linearly before
  * performing consulting above data structures for more efficient lookups. For
  * non rotational devices, this value defaults to 0 and for rotational devices