When counting down the counter start from preset value
and fire event when reach 0.
-What: /sys/bus/iio/devices/iio:deviceX/in_count_quadrature_mode_available
-KernelVersion: 4.12
-Contact: benjamin.gaignard@st.com
-Description:
- Reading returns the list possible quadrature modes.
-
-What: /sys/bus/iio/devices/iio:deviceX/in_count0_quadrature_mode
-KernelVersion: 4.12
-Contact: benjamin.gaignard@st.com
-Description:
- Configure the device counter quadrature modes:
-
- channel_A:
- Encoder A input servers as the count input and B as
- the UP/DOWN direction control input.
-
- channel_B:
- Encoder B input serves as the count input and A as
- the UP/DOWN direction control input.
-
- quadrature:
- Encoder A and B inputs are mixed to get direction
- and count with a scale of 0.25.
-
What: /sys/bus/iio/devices/iio:deviceX/in_count_enable_mode_available
KernelVersion: 4.12
Contact: benjamin.gaignard@st.com