Commit
a3ae5b057588f555a1544ec749167a44c5a071aa ("Update documentation
on log file formats") added documentation for the log format but left
out the block size column so let's add it here.
While we're here clean up some formatting in log_offset, add a reference
to Log File Formats and mention that it defaults to off.
Signed-off-by: Sitsofe Wheeler <sitsofe@yahoo.com>
.. option:: log_offset=int
If this is set, the iolog options will include the byte offset for the I/O
.. option:: log_offset=int
If this is set, the iolog options will include the byte offset for the I/O
- entry as well as the other data values.
+ entry as well as the other data values. Defaults to 0 meaning that
+ offsets are not present in logs. Also see `Log File Formats`_.
.. option:: log_compression=int
.. option:: log_compression=int
Fio supports a variety of log file formats, for logging latencies, bandwidth,
and IOPS. The logs share a common format, which looks like this:
Fio supports a variety of log file formats, for logging latencies, bandwidth,
and IOPS. The logs share a common format, which looks like this:
- *time* (`msec`), *value*, *data direction*, *offset*
+ *time* (`msec`), *value*, *data direction*, *block size* (`bytes`),
+ *offset* (`bytes`)
-Time for the log entry is always in milliseconds. The *value* logged depends
+*Time* for the log entry is always in milliseconds. The *value* logged depends
on the type of log, it will be one of the following:
**Latency log**
on the type of log, it will be one of the following:
**Latency log**
-The *offset* is the offset, in bytes, from the start of the file, for that
-particular I/O. The logging of the offset can be toggled with
-:option:`log_offset`.
+The entry's *block size* is always in bytes. The *offset* is the offset, in bytes,
+from the start of the file, for that particular I/O. The logging of the offset can be
+toggled with :option:`log_offset`.
Fio defaults to logging every individual I/O. When IOPS are logged for individual
Fio defaults to logging every individual I/O. When IOPS are logged for individual
-I/Os the value entry will always be 1. If windowed logging is enabled through
+I/Os the *value* entry will always be 1. If windowed logging is enabled through
:option:`log_avg_msec`, fio logs the average values over the specified period of time.
If windowed logging is enabled and :option:`log_max_value` is set, then fio logs
:option:`log_avg_msec`, fio logs the average values over the specified period of time.
If windowed logging is enabled and :option:`log_max_value` is set, then fio logs
-maximum values in that window instead of averages. Since 'data direction' and
-'offset' are per-I/O values, they aren't applicable if windowed logging is enabled.
+maximum values in that window instead of averages. Since *data direction*, *block
+size* and *offset* are per-I/O values, if windowed logging is enabled they
+aren't applicable and will be 0.
Client/Server
-------------
Client/Server
-------------
.TP
.BI log_offset \fR=\fPbool
If this is set, the iolog options will include the byte offset for the IO
.TP
.BI log_offset \fR=\fPbool
If this is set, the iolog options will include the byte offset for the IO
-entry as well as the other data values.
+entry as well as the other data values. Defaults to 0 meaning that offsets are
+not present in logs. See the \fBLOG FILE FORMATS\fR section.
.TP
.BI log_compression \fR=\fPint
If this is set, fio will compress the IO logs as it goes, to keep the memory
.TP
.BI log_compression \fR=\fPint
If this is set, fio will compress the IO logs as it goes, to keep the memory
Fio supports a variety of log file formats, for logging latencies, bandwidth,
and IOPS. The logs share a common format, which looks like this:
Fio supports a variety of log file formats, for logging latencies, bandwidth,
and IOPS. The logs share a common format, which looks like this:
-.B time (msec), value, data direction, offset
+.B time (msec), value, data direction, block size (bytes), offset (bytes)
Time for the log entry is always in milliseconds. The value logged depends
on the type of log, it will be one of the following:
Time for the log entry is always in milliseconds. The value logged depends
on the type of log, it will be one of the following:
-The \fIoffset\fR is the offset, in bytes, from the start of the file, for that
-particular IO. The logging of the offset can be toggled with \fBlog_offset\fR.
+The entry's *block size* is always in bytes. The \fIoffset\fR is the offset, in
+bytes, from the start of the file, for that particular IO. The logging of the
+offset can be toggled with \fBlog_offset\fR.
If windowed logging is enabled through \fBlog_avg_msec\fR, then fio doesn't log
individual IOs. Instead of logs the average values over the specified
If windowed logging is enabled through \fBlog_avg_msec\fR, then fio doesn't log
individual IOs. Instead of logs the average values over the specified
-period of time. Since \fIdata direction\fR and \fIoffset\fR are per-IO values,
-they aren't applicable if windowed logging is enabled. If windowed logging
-is enabled and \fBlog_max_value\fR is set, then fio logs maximum values in
-that window instead of averages.
+period of time. Since \fIdata direction\fR, \fIblock size\fR and \fIoffset\fR
+are per-IO values, if windowed logging is enabled they aren't applicable and
+will be 0. If windowed logging is enabled and \fBlog_max_value\fR is set, then
+fio logs maximum values in that window instead of averages.
For histogram logging the logs look like this: