hwmon: (mr75203) fix wrong power-up delay value
authorArseny Demidov <arsdemal@gmail.com>
Sun, 19 Dec 2021 10:22:39 +0000 (13:22 +0300)
committerGreg Kroah-Hartman <gregkh@linuxfoundation.org>
Thu, 27 Jan 2022 09:54:00 +0000 (10:54 +0100)
commitdf126818192814cd8981c42bd15f79d3e312a073
tree7b671799db91c26fa6541537422cafc980293ba8
parentaea5302d9ddc8c9f637393c63d824f45026e906e
hwmon: (mr75203) fix wrong power-up delay value

[ Upstream commit a8d6d4992ad9d92356619ac372906bd29687bb46 ]

In the file mr75203.c we have a macro named POWER_DELAY_CYCLE_256,
the correct value should be 0x100. The register ip_tmr is expressed
in units of IP clk cycles, in accordance with the datasheet.
Typical power-up delays for Temperature Sensor are 256 cycles i.e. 0x100.

Fixes: 9d823351a337 ("hwmon: Add hardware monitoring driver for Moortec MR75203 PVT controller")
Signed-off-by: Arseny Demidov <a.demidov@yadro.com>
Link: https://lore.kernel.org/r/20211219102239.1112-1-a.demidov@yadro.com
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
Signed-off-by: Sasha Levin <sashal@kernel.org>
drivers/hwmon/mr75203.c