staging: iio: resolver: ad2s1210: do not use fault register for dummy read
authorDavid Lechner <dlechner@baylibre.com>
Fri, 6 Oct 2023 00:50:18 +0000 (19:50 -0500)
committerJonathan Cameron <Jonathan.Cameron@huawei.com>
Wed, 11 Oct 2023 14:54:40 +0000 (15:54 +0100)
commitd97d11c70f25726fc21b2b2f1a26e16ac96a8ccf
treee116e896e00d77ef28aceb56ad54f6588a17a3f3
parent6eb14ffa1873d756b9141837720ff70f07d849f1
staging: iio: resolver: ad2s1210: do not use fault register for dummy read

When reading registers on the AD2S1210 chip, we have to supply a "dummy"
address for the second SPI tx byte so that we don't accidentally write
to a register. This register will be read and the value discarded on the
next regmap read or write call.

Reading the fault register has a side-effect of clearing the faults
so we should not use this register for the dummy read.

Signed-off-by: David Lechner <dlechner@baylibre.com>
Link: https://lore.kernel.org/r/20231005-ad2s1210-mainline-v4-1-ec00746840fc@baylibre.com
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
drivers/staging/iio/resolver/ad2s1210.c