scsi: mpi3mr: Serialize admin queue BAR writes on 32-bit systems
On 32-bit systems, 64-bit BAR writes to admin queue registers are
performed as two 32-bit writes. Without locking, this can cause partial
writes when accessed concurrently.
Updated per-queue spinlocks is used to serialize these writes and prevent
race conditions.
Fixes:
824a156633df ("scsi: mpi3mr: Base driver code")
Cc: stable@vger.kernel.org
Signed-off-by: Ranjan Kumar <ranjan.kumar@broadcom.com>
Link: https://lore.kernel.org/r/20250627194539.48851-4-ranjan.kumar@broadcom.com