power: supply: bq27xxx: Move temperature reading out of update loop
authorAndrew Davis <afd@ti.com>
Mon, 25 Mar 2024 20:31:24 +0000 (15:31 -0500)
committerSebastian Reichel <sebastian.reichel@collabora.com>
Mon, 1 Apr 2024 10:29:44 +0000 (12:29 +0200)
commitc32c617de8076d8fb2a16a4a2f3b5da5f3df398d
tree7261ba89a481d9145948f2ffc8c9768659c19fd3
parentd6486a13665e9df5b503a375e18226e1824f21d3
power: supply: bq27xxx: Move temperature reading out of update loop

Most of the functions that read values return a status and put the value
itself in an a function parameter. Update temperature reading to match.

As temp is not checked for changes as part of the update loop, remove
the read of the temperature from the periodic update loop. This saves
I2C/1W bandwidth. It also means we do not have to cache it, fresh
values are read when requested.

Signed-off-by: Andrew Davis <afd@ti.com>
Link: https://lore.kernel.org/r/20240325203129.150030-1-afd@ti.com
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
drivers/power/supply/bq27xxx_battery.c