net/mlx5: Read embedded cpu after init bit cleared
During driver load it reads embedded_cpu bit from initialization
segment, but the initialization segment is readable only after
initialization bit is cleared.
Move the call to mlx5_read_embedded_cpu() right after initialization bit
cleared.
Signed-off-by: Moshe Shemesh <moshe@nvidia.com>
Fixes:
591905ba9679 ("net/mlx5: Introduce Mellanox SmartNIC and modify page management logic")
Reviewed-by: Shay Drory <shayd@nvidia.com>
Signed-off-by: Saeed Mahameed <saeedm@nvidia.com>