iio: adc: ad_sigma_delta: add disable_one callback
authorDumitru Ceclan <dumitru.ceclan@analog.com>
Fri, 7 Jun 2024 14:53:09 +0000 (17:53 +0300)
committerJonathan Cameron <Jonathan.Cameron@huawei.com>
Tue, 25 Jun 2024 20:04:32 +0000 (21:04 +0100)
commit98a563de231fcc91d65c6028c7f646fe28faf83a
treea0e824ea0e9cc579c4e2c216c826c17eba0f6b94
parent561b5d5b7fbc1475e62ae68309f667ad2e18a669
iio: adc: ad_sigma_delta: add disable_one callback

Sigma delta ADCs with a sequencer need to disable the previously enabled
channel when reading using ad_sigma_delta_single_conversion(). This was
done manually in drivers for devices with sequencers.

This patch implements handling of single channel disabling after a
single conversion.

Reviewed-by: Nuno Sa <nuno.sa@analog.com>
Signed-off-by: Dumitru Ceclan <dumitru.ceclan@analog.com>
Reviewed-by: David Lechner <dlechner@baylibre.com>
Link: https://patch.msgid.link/20240607-ad4111-v7-3-97e3855900a0@analog.com
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
drivers/iio/adc/ad7124.c
drivers/iio/adc/ad7173.c
drivers/iio/adc/ad_sigma_delta.c
include/linux/iio/adc/ad_sigma_delta.h