hwmon: (max31790) Report correct current pwm duty cycles
authorGuenter Roeck <linux@roeck-us.net>
Wed, 26 May 2021 15:40:17 +0000 (08:40 -0700)
committerGuenter Roeck <linux@roeck-us.net>
Thu, 17 Jun 2021 11:21:45 +0000 (04:21 -0700)
commit897f6339893b741a5d68ae8e2475df65946041c2
treeca031eaff13b0fc6d244be34777e3bcc13eb82e4
parentcbbf244f0515af3472084f22b6213121b4a63835
hwmon: (max31790) Report correct current pwm duty cycles

The MAX31790 has two sets of registers for pwm duty cycles, one to request
a duty cycle and one to read the actual current duty cycle. Both do not
have to be the same.

When reporting the pwm duty cycle to the user, the actual pwm duty cycle
from pwm duty cycle registers needs to be reported. When setting it, the
pwm target duty cycle needs to be written. Since we don't know the actual
pwm duty cycle after a target pwm duty cycle has been written, set the
valid flag to false to indicate that actual pwm duty cycle should be read
from the chip instead of using cached values.

Cc: Jan Kundrát <jan.kundrat@cesnet.cz>
Cc: Václav Kubernát <kubernat@cesnet.cz>
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
Tested-by: Václav Kubernát <kubernat@ceesnet.cz>
Reviewed-by: Jan Kundrát <jan.kundrat@cesnet.cz>
Link: https://lore.kernel.org/r/20210526154022.3223012-3-linux@roeck-us.net
Documentation/hwmon/max31790.rst
drivers/hwmon/max31790.c