iio: cros_ec: Set Gyroscope default frequency to 25Hz
authorGwendal Grignou <gwendal@chromium.org>
Tue, 28 Jul 2020 20:48:25 +0000 (13:48 -0700)
committerGreg Kroah-Hartman <gregkh@linuxfoundation.org>
Thu, 17 Sep 2020 11:55:38 +0000 (13:55 +0200)
commit678f5426826944e94b5500f874e4ca200fe77052
tree5221f98998a7141a20256bafc511b014e4b6ed56
parent79d1a06c5940fafd0957d1029e9cc07009489d13
iio: cros_ec: Set Gyroscope default frequency to 25Hz

commit 336306790b2bbf7ce837625fa3b24ba724d05838 upstream.

BMI160 Minimium gyroscope frequency in normal mode is 25Hz.
When older EC firmware do not report their sensors frequencies,
use 25Hz as the minimum for gyroscope to be sure it works on BMI160.

Fixes: ae7b02ad2f32d ("iio: common: cros_ec_sensors: Expose cros_ec_sensors frequency range via iio sysfs")
Signed-off-by: Gwendal Grignou <gwendal@chromium.org>
Reviewed-by: Enric Balletbo i Serra <enric.balletbo@collabora.com>
Cc: <Stable@vger.kernel.org>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>