power: supply: core: add POWER_SUPPLY_HEALTH_CALIBRATION_REQUIRED
authorSebastian Reichel <sebastian.reichel@collabora.com>
Wed, 13 May 2020 18:56:00 +0000 (20:56 +0200)
committerSebastian Reichel <sebastian.reichel@collabora.com>
Thu, 28 May 2020 17:25:31 +0000 (19:25 +0200)
commit601c2a543f02da484362b3ff9074b2cfe08750de
tree69e8aad4e7ec6a181d22ec9dcb99135f3aba770c
parentfeabe49e46bb556b8d43e28d4a0d459940f7a5cb
power: supply: core: add POWER_SUPPLY_HEALTH_CALIBRATION_REQUIRED

Some battery fuel gauges know when the battery needs to
be recalibrated before providing usable values. This
should be reported via the health property.

Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
Documentation/ABI/testing/sysfs-class-power
drivers/power/supply/power_supply_sysfs.c
include/linux/power_supply.h