clk: samsung: s3c2410: Fix PLL rates
authorAndrzej Hajda <a.hajda@samsung.com>
Fri, 16 Feb 2018 14:57:53 +0000 (15:57 +0100)
committerSylwester Nawrocki <s.nawrocki@samsung.com>
Fri, 23 Feb 2018 14:15:16 +0000 (15:15 +0100)
commit179db533c08431f509a3823077549773d519358b
tree90a9b62fc4687a61d2b3cc5702d800e03c723731
parent7e4db0c2836e892766565965207eee051c8037b9
clk: samsung: s3c2410: Fix PLL rates

Rates declared in PLL rate tables should match exactly rates calculated from
the PLL coefficients. If that is not the case, rate of the PLL's child clock
might be set not as expected. For instance, if in the PLL rates table we have
393216000 Hz entry and the real value as returned by the PLL's recalc_rate
callback is 393216003, after setting PLL's clk rate to 393216000 clk_get_rate
will return 393216003. If we now attempt to set rate of a PLL's child divider
clock to 393216000/2 its rate will be 131072001, rather than 196608000.
That is, the divider will be set to 3 instead of 2, because 393216003/2 is
greater than 196608000.

To fix this issue declared rates are changed to exactly match rates generated
by the PLL, as calculated from the P, M, S, K coefficients.

Signed-off-by: Andrzej Hajda <a.hajda@samsung.com>
Acked-by: Tomasz Figa <tomasz.figa@gmail.com>
Acked-by: Chanwoo Choi <cw00.choi@samsung.com>
Signed-off-by: Sylwester Nawrocki <s.nawrocki@samsung.com>
drivers/clk/samsung/clk-s3c2410.c