Bluetooth: Set Scan PHYs based on selected PHYs by user
Use the PHYs selected in Set Phy Configuration management command
while scanning.
< HCI Command: LE Set Extended Scan Parameters (0x08|0x0041) plen 13
Own address type: Random (0x01)
Filter policy: Accept all advertisement (0x00)
PHYs: 0x05
Entry 0: LE 1M
Type: Active (0x01)
Interval: 11.250 msec (0x0012)
Window: 11.250 msec (0x0012)
Entry 1: LE Coded
Type: Active (0x01)
Interval: 11.250 msec (0x0012)
Window: 11.250 msec (0x0012)
> HCI Event: Command Complete (0x0e) plen 4
LE Set Extended Scan Parameters (0x08|0x0041) ncmd 1
Status: Success (0x00)
< HCI Command: LE Set Extended Scan Enable (0x08|0x0042) plen 6
Extended scan: Enabled (0x01)
Filter duplicates: Enabled (0x01)
Duration: 0 msec (0x0000)
Period: 0.00 sec (0x0000)
> HCI Event: Command Complete (0x0e) plen 4
LE Set Extended Scan Enable (0x08|0x0042) ncmd 2
Status: Success (0x00)
Signed-off-by: Jaganath Kanakkassery <jaganathx.kanakkassery@intel.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>