1 config INTEL_POWERCLAMP
2         tristate "Intel PowerClamp idle injection driver"
3         depends on X86
4         depends on CPU_SUP_INTEL
5         help
6           Enable this to enable Intel PowerClamp idle injection driver. This
7           enforce idle time which results in more package C-state residency. The
8           user interface is exposed via generic thermal framework.
9
10 config X86_PKG_TEMP_THERMAL
11         tristate "X86 package temperature thermal driver"
12         depends on X86_THERMAL_VECTOR
13         select THERMAL_GOV_USER_SPACE
14         select THERMAL_WRITABLE_TRIPS
15         default m
16         help
17           Enable this to register CPU digital sensor for package temperature as
18           thermal zone. Each package will have its own thermal zone. There are
19           two trip points which can be set by user to get notifications via thermal
20           notification methods.
21
22 config INTEL_SOC_DTS_IOSF_CORE
23         tristate
24         depends on X86 && PCI
25         select IOSF_MBI
26         help
27           This is becoming a common feature for Intel SoCs to expose the additional
28           digital temperature sensors (DTSs) using side band interface (IOSF). This
29           implements the common set of helper functions to register, get temperature
30           and get/set thresholds on DTSs.
31
32 config INTEL_SOC_DTS_THERMAL
33         tristate "Intel SoCs DTS thermal driver"
34         depends on X86 && PCI && ACPI
35         select INTEL_SOC_DTS_IOSF_CORE
36         select THERMAL_WRITABLE_TRIPS
37         help
38           Enable this to register Intel SoCs (e.g. Bay Trail) platform digital
39           temperature sensor (DTS). These SoCs have two additional DTSs in
40           addition to DTSs on CPU cores. Each DTS will be registered as a
41           thermal zone. There are two trip points. One of the trip point can
42           be set by user mode programs to get notifications via Linux thermal
43           notification methods.The other trip is a critical trip point, which
44           was set by the driver based on the TJ MAX temperature.
45
46 config INTEL_QUARK_DTS_THERMAL
47         tristate "Intel Quark DTS thermal driver"
48         depends on X86_INTEL_QUARK
49         help
50           Enable this to register Intel Quark SoC (e.g. X1000) platform digital
51           temperature sensor (DTS). For X1000 SoC, it has one on-die DTS.
52           The DTS will be registered as a thermal zone. There are two trip points:
53           hot & critical. The critical trip point default value is set by
54           underlying BIOS/Firmware.
55
56 menu "ACPI INT340X thermal drivers"
57 source "drivers/thermal/intel/int340x_thermal/Kconfig"
58 endmenu
59
60 config INTEL_BXT_PMIC_THERMAL
61         tristate "Intel Broxton PMIC thermal driver"
62         depends on X86 && INTEL_SOC_PMIC_BXTWC && REGMAP
63         help
64           Select this driver for Intel Broxton PMIC with ADC channels monitoring
65           system temperature measurements and alerts.
66           This driver is used for monitoring the ADC channels of PMIC and handles
67           the alert trip point interrupts and notifies the thermal framework with
68           the trip point and temperature details of the zone.
69
70 config INTEL_PCH_THERMAL
71         tristate "Intel PCH Thermal Reporting Driver"
72         depends on X86 && PCI
73         help
74           Enable this to support thermal reporting on certain intel PCHs.