1 #
2 # Generic thermal sysfs drivers configuration
3 #
4
5 menuconfig THERMAL
6         tristate "Generic Thermal sysfs driver"
7         help
8           Generic Thermal Sysfs driver offers a generic mechanism for
9           thermal management. Usually it's made up of one or more thermal
10           zone and cooling device.
11           Each thermal zone contains its own temperature, trip points,
12           cooling devices.
13           All platforms with ACPI thermal support can use this driver.
14           If you want this support, you should say Y or M here.
15
16 if THERMAL
17
18 config THERMAL_HWMON
19         bool
20         depends on HWMON=y || HWMON=THERMAL
21         default y
22
23 choice
24         prompt "Default Thermal governor"
25         default THERMAL_DEFAULT_GOV_STEP_WISE
26         help
27           This option sets which thermal governor shall be loaded at
28           startup. If in doubt, select 'step_wise'.
29
30 config THERMAL_DEFAULT_GOV_STEP_WISE
31         bool "step_wise"
32         select THERMAL_GOV_STEP_WISE
33         help
34           Use the step_wise governor as default. This throttles the
35           devices one step at a time.
36
37 config THERMAL_DEFAULT_GOV_FAIR_SHARE
38         bool "fair_share"
39         select THERMAL_GOV_FAIR_SHARE
40         help
41           Use the fair_share governor as default. This throttles the
42           devices based on their 'contribution' to a zone. The
43           contribution should be provided through platform data.
44
45 config THERMAL_DEFAULT_GOV_USER_SPACE
46         bool "user_space"
47         select THERMAL_GOV_USER_SPACE
48         help
49           Select this if you want to let the user space manage the
50           lpatform thermals.
51
52 endchoice
53
54 config THERMAL_GOV_FAIR_SHARE
55         bool "Fair-share thermal governor"
56         help
57           Enable this to manage platform thermals using fair-share governor.
58
59 config THERMAL_GOV_STEP_WISE
60         bool "Step_wise thermal governor"
61         help
62           Enable this to manage platform thermals using a simple linear
63
64 config THERMAL_GOV_USER_SPACE
65         bool "User_space thermal governor"
66         help
67           Enable this to let the user space manage the platform thermals.
68
69 config CPU_THERMAL
70         tristate "generic cpu cooling support"
71         depends on CPU_FREQ
72         select CPU_FREQ_TABLE
73         help
74           This implements the generic cpu cooling mechanism through frequency
75           reduction, cpu hotplug and any other ways of reducing temperature. An
76           ACPI version of this already exists(drivers/acpi/processor_thermal.c).
77           This will be useful for platforms using the generic thermal interface
78           and not the ACPI interface.
79           If you want this support, you should say Y here.
80
81 config THERMAL_EMULATION
82         bool "Thermal emulation mode support"
83         help
84           Enable this option to make a emul_temp sysfs node in thermal zone
85           directory to support temperature emulation. With emulation sysfs node,
86           user can manually input temperature and test the different trip
87           threshold behaviour for simulation purpose.
88
89           WARNING: Be careful while enabling this option on production systems,
90           because userland can easily disable the thermal policy by simply
91           flooding this sysfs node with low temperature values.
92
93 config SPEAR_THERMAL
94         bool "SPEAr thermal sensor driver"
95         depends on PLAT_SPEAR
96         depends on OF
97         help
98           Enable this to plug the SPEAr thermal sensor driver into the Linux
99           thermal framework
100
101 config RCAR_THERMAL
102         tristate "Renesas R-Car thermal driver"
103         depends on ARCH_SHMOBILE
104         help
105           Enable this to plug the R-Car thermal sensor driver into the Linux
106           thermal framework
107
108 config KIRKWOOD_THERMAL
109         tristate "Temperature sensor on Marvell Kirkwood SoCs"
110         depends on ARCH_KIRKWOOD
111         depends on OF
112         help
113           Support for the Kirkwood thermal sensor driver into the Linux thermal
114           framework. Only kirkwood 88F6282 and 88F6283 have this sensor.
115
116 config EXYNOS_THERMAL
117         tristate "Temperature sensor on Samsung EXYNOS"
118         depends on (ARCH_EXYNOS4 || ARCH_EXYNOS5)
119         depends on CPU_THERMAL
120         help
121           If you say yes here you get support for TMU (Thermal Management
122           Unit) on SAMSUNG EXYNOS series of SoC.
123
124 config DOVE_THERMAL
125         tristate "Temperature sensor on Marvell Dove SoCs"
126         depends on ARCH_DOVE
127         depends on OF
128         help
129           Support for the Dove thermal sensor driver in the Linux thermal
130           framework.
131
132 config DB8500_THERMAL
133         bool "DB8500 thermal management"
134         depends on ARCH_U8500
135         default y
136         help
137           Adds DB8500 thermal management implementation according to the thermal
138           management framework. A thermal zone with several trip points will be
139           created. Cooling devices can be bound to the trip points to cool this
140           thermal zone if trip points reached.
141
142 config ARMADA_THERMAL
143         tristate "Armada 370/XP thermal management"
144         depends on ARCH_MVEBU
145         depends on OF
146         help
147           Enable this option if you want to have support for thermal management
148           controller present in Armada 370 and Armada XP SoC.
149
150 config DB8500_CPUFREQ_COOLING
151         tristate "DB8500 cpufreq cooling"
152         depends on ARCH_U8500
153         depends on CPU_THERMAL
154         default y
155         help
156           Adds DB8500 cpufreq cooling devices, and these cooling devices can be
157           bound to thermal zone trip points. When a trip point reached, the
158           bound cpufreq cooling device turns active to set CPU frequency low to
159           cool down the CPU.
160
161 config INTEL_POWERCLAMP
162         tristate "Intel PowerClamp idle injection driver"
163         depends on THERMAL
164         depends on X86
165         depends on CPU_SUP_INTEL
166         help
167           Enable this to enable Intel PowerClamp idle injection driver. This
168           enforce idle time which results in more package C-state residency. The
169           user interface is exposed via generic thermal framework.