Merge remote-tracking branches 'asoc/topic/adau17x1', 'asoc/topic/adsp', 'asoc/topic...
[linux-2.6-block.git] / drivers / md / Kconfig
1 #
2 # Block device driver configuration
3 #
4
5 menuconfig MD
6         bool "Multiple devices driver support (RAID and LVM)"
7         depends on BLOCK
8         select SRCU
9         help
10           Support multiple physical spindles through a single logical device.
11           Required for RAID and logical volume management.
12
13 if MD
14
15 config BLK_DEV_MD
16         tristate "RAID support"
17         ---help---
18           This driver lets you combine several hard disk partitions into one
19           logical block device. This can be used to simply append one
20           partition to another one or to combine several redundant hard disks
21           into a RAID1/4/5 device so as to provide protection against hard
22           disk failures. This is called "Software RAID" since the combining of
23           the partitions is done by the kernel. "Hardware RAID" means that the
24           combining is done by a dedicated controller; if you have such a
25           controller, you do not need to say Y here.
26
27           More information about Software RAID on Linux is contained in the
28           Software RAID mini-HOWTO, available from
29           <http://www.tldp.org/docs.html#howto>. There you will also learn
30           where to get the supporting user space utilities raidtools.
31
32           If unsure, say N.
33
34 config MD_AUTODETECT
35         bool "Autodetect RAID arrays during kernel boot"
36         depends on BLK_DEV_MD=y
37         default y
38         ---help---
39           If you say Y here, then the kernel will try to autodetect raid
40           arrays as part of its boot process. 
41
42           If you don't use raid and say Y, this autodetection can cause 
43           a several-second delay in the boot time due to various
44           synchronisation steps that are part of this step.
45
46           If unsure, say Y.
47
48 config MD_LINEAR
49         tristate "Linear (append) mode"
50         depends on BLK_DEV_MD
51         ---help---
52           If you say Y here, then your multiple devices driver will be able to
53           use the so-called linear mode, i.e. it will combine the hard disk
54           partitions by simply appending one to the other.
55
56           To compile this as a module, choose M here: the module
57           will be called linear.
58
59           If unsure, say Y.
60
61 config MD_RAID0
62         tristate "RAID-0 (striping) mode"
63         depends on BLK_DEV_MD
64         ---help---
65           If you say Y here, then your multiple devices driver will be able to
66           use the so-called raid0 mode, i.e. it will combine the hard disk
67           partitions into one logical device in such a fashion as to fill them
68           up evenly, one chunk here and one chunk there. This will increase
69           the throughput rate if the partitions reside on distinct disks.
70
71           Information about Software RAID on Linux is contained in the
72           Software-RAID mini-HOWTO, available from
73           <http://www.tldp.org/docs.html#howto>. There you will also
74           learn where to get the supporting user space utilities raidtools.
75
76           To compile this as a module, choose M here: the module
77           will be called raid0.
78
79           If unsure, say Y.
80
81 config MD_RAID1
82         tristate "RAID-1 (mirroring) mode"
83         depends on BLK_DEV_MD
84         ---help---
85           A RAID-1 set consists of several disk drives which are exact copies
86           of each other.  In the event of a mirror failure, the RAID driver
87           will continue to use the operational mirrors in the set, providing
88           an error free MD (multiple device) to the higher levels of the
89           kernel.  In a set with N drives, the available space is the capacity
90           of a single drive, and the set protects against a failure of (N - 1)
91           drives.
92
93           Information about Software RAID on Linux is contained in the
94           Software-RAID mini-HOWTO, available from
95           <http://www.tldp.org/docs.html#howto>.  There you will also
96           learn where to get the supporting user space utilities raidtools.
97
98           If you want to use such a RAID-1 set, say Y.  To compile this code
99           as a module, choose M here: the module will be called raid1.
100
101           If unsure, say Y.
102
103 config MD_RAID10
104         tristate "RAID-10 (mirrored striping) mode"
105         depends on BLK_DEV_MD
106         ---help---
107           RAID-10 provides a combination of striping (RAID-0) and
108           mirroring (RAID-1) with easier configuration and more flexible
109           layout.
110           Unlike RAID-0, but like RAID-1, RAID-10 requires all devices to
111           be the same size (or at least, only as much as the smallest device
112           will be used).
113           RAID-10 provides a variety of layouts that provide different levels
114           of redundancy and performance.
115
116           RAID-10 requires mdadm-1.7.0 or later, available at:
117
118           ftp://ftp.kernel.org/pub/linux/utils/raid/mdadm/
119
120           If unsure, say Y.
121
122 config MD_RAID456
123         tristate "RAID-4/RAID-5/RAID-6 mode"
124         depends on BLK_DEV_MD
125         select RAID6_PQ
126         select LIBCRC32C
127         select ASYNC_MEMCPY
128         select ASYNC_XOR
129         select ASYNC_PQ
130         select ASYNC_RAID6_RECOV
131         ---help---
132           A RAID-5 set of N drives with a capacity of C MB per drive provides
133           the capacity of C * (N - 1) MB, and protects against a failure
134           of a single drive. For a given sector (row) number, (N - 1) drives
135           contain data sectors, and one drive contains the parity protection.
136           For a RAID-4 set, the parity blocks are present on a single drive,
137           while a RAID-5 set distributes the parity across the drives in one
138           of the available parity distribution methods.
139
140           A RAID-6 set of N drives with a capacity of C MB per drive
141           provides the capacity of C * (N - 2) MB, and protects
142           against a failure of any two drives. For a given sector
143           (row) number, (N - 2) drives contain data sectors, and two
144           drives contains two independent redundancy syndromes.  Like
145           RAID-5, RAID-6 distributes the syndromes across the drives
146           in one of the available parity distribution methods.
147
148           Information about Software RAID on Linux is contained in the
149           Software-RAID mini-HOWTO, available from
150           <http://www.tldp.org/docs.html#howto>. There you will also
151           learn where to get the supporting user space utilities raidtools.
152
153           If you want to use such a RAID-4/RAID-5/RAID-6 set, say Y.  To
154           compile this code as a module, choose M here: the module
155           will be called raid456.
156
157           If unsure, say Y.
158
159 config MD_MULTIPATH
160         tristate "Multipath I/O support"
161         depends on BLK_DEV_MD
162         help
163           MD_MULTIPATH provides a simple multi-path personality for use
164           the MD framework.  It is not under active development.  New
165           projects should consider using DM_MULTIPATH which has more
166           features and more testing.
167
168           If unsure, say N.
169
170 config MD_FAULTY
171         tristate "Faulty test module for MD"
172         depends on BLK_DEV_MD
173         help
174           The "faulty" module allows for a block device that occasionally returns
175           read or write errors.  It is useful for testing.
176
177           In unsure, say N.
178
179
180 config MD_CLUSTER
181         tristate "Cluster Support for MD (EXPERIMENTAL)"
182         depends on BLK_DEV_MD
183         depends on DLM
184         default n
185         ---help---
186         Clustering support for MD devices. This enables locking and
187         synchronization across multiple systems on the cluster, so all
188         nodes in the cluster can access the MD devices simultaneously.
189
190         This brings the redundancy (and uptime) of RAID levels across the
191         nodes of the cluster.
192
193         If unsure, say N.
194
195 source "drivers/md/bcache/Kconfig"
196
197 config BLK_DEV_DM_BUILTIN
198         bool
199
200 config BLK_DEV_DM
201         tristate "Device mapper support"
202         select BLK_DEV_DM_BUILTIN
203         ---help---
204           Device-mapper is a low level volume manager.  It works by allowing
205           people to specify mappings for ranges of logical sectors.  Various
206           mapping types are available, in addition people may write their own
207           modules containing custom mappings if they wish.
208
209           Higher level volume managers such as LVM2 use this driver.
210
211           To compile this as a module, choose M here: the module will be
212           called dm-mod.
213
214           If unsure, say N.
215
216 config DM_MQ_DEFAULT
217         bool "request-based DM: use blk-mq I/O path by default"
218         depends on BLK_DEV_DM
219         ---help---
220           This option enables the blk-mq based I/O path for request-based
221           DM devices by default.  With the option the dm_mod.use_blk_mq
222           module/boot option defaults to Y, without it to N, but it can
223           still be overriden either way.
224
225           If unsure say N.
226
227 config DM_DEBUG
228         bool "Device mapper debugging support"
229         depends on BLK_DEV_DM
230         ---help---
231           Enable this for messages that may help debug device-mapper problems.
232
233           If unsure, say N.
234
235 config DM_BUFIO
236        tristate
237        depends on BLK_DEV_DM
238        ---help---
239          This interface allows you to do buffered I/O on a device and acts
240          as a cache, holding recently-read blocks in memory and performing
241          delayed writes.
242
243 config DM_DEBUG_BLOCK_MANAGER_LOCKING
244        bool "Block manager locking"
245        depends on DM_BUFIO
246        ---help---
247          Block manager locking can catch various metadata corruption issues.
248
249          If unsure, say N.
250
251 config DM_DEBUG_BLOCK_STACK_TRACING
252        bool "Keep stack trace of persistent data block lock holders"
253        depends on STACKTRACE_SUPPORT && DM_DEBUG_BLOCK_MANAGER_LOCKING
254        select STACKTRACE
255        ---help---
256          Enable this for messages that may help debug problems with the
257          block manager locking used by thin provisioning and caching.
258
259          If unsure, say N.
260
261 config DM_BIO_PRISON
262        tristate
263        depends on BLK_DEV_DM
264        ---help---
265          Some bio locking schemes used by other device-mapper targets
266          including thin provisioning.
267
268 source "drivers/md/persistent-data/Kconfig"
269
270 config DM_CRYPT
271         tristate "Crypt target support"
272         depends on BLK_DEV_DM
273         select CRYPTO
274         select CRYPTO_CBC
275         ---help---
276           This device-mapper target allows you to create a device that
277           transparently encrypts the data on it. You'll need to activate
278           the ciphers you're going to use in the cryptoapi configuration.
279
280           For further information on dm-crypt and userspace tools see:
281           <https://gitlab.com/cryptsetup/cryptsetup/wikis/DMCrypt>
282
283           To compile this code as a module, choose M here: the module will
284           be called dm-crypt.
285
286           If unsure, say N.
287
288 config DM_SNAPSHOT
289        tristate "Snapshot target"
290        depends on BLK_DEV_DM
291        select DM_BUFIO
292        ---help---
293          Allow volume managers to take writable snapshots of a device.
294
295 config DM_THIN_PROVISIONING
296        tristate "Thin provisioning target"
297        depends on BLK_DEV_DM
298        select DM_PERSISTENT_DATA
299        select DM_BIO_PRISON
300        ---help---
301          Provides thin provisioning and snapshots that share a data store.
302
303 config DM_CACHE
304        tristate "Cache target (EXPERIMENTAL)"
305        depends on BLK_DEV_DM
306        default n
307        select DM_PERSISTENT_DATA
308        select DM_BIO_PRISON
309        ---help---
310          dm-cache attempts to improve performance of a block device by
311          moving frequently used data to a smaller, higher performance
312          device.  Different 'policy' plugins can be used to change the
313          algorithms used to select which blocks are promoted, demoted,
314          cleaned etc.  It supports writeback and writethrough modes.
315
316 config DM_CACHE_SMQ
317        tristate "Stochastic MQ Cache Policy (EXPERIMENTAL)"
318        depends on DM_CACHE
319        default y
320        ---help---
321          A cache policy that uses a multiqueue ordered by recent hits
322          to select which blocks should be promoted and demoted.
323          This is meant to be a general purpose policy.  It prioritises
324          reads over writes.  This SMQ policy (vs MQ) offers the promise
325          of less memory utilization, improved performance and increased
326          adaptability in the face of changing workloads.
327
328 config DM_CACHE_CLEANER
329        tristate "Cleaner Cache Policy (EXPERIMENTAL)"
330        depends on DM_CACHE
331        default y
332        ---help---
333          A simple cache policy that writes back all data to the
334          origin.  Used when decommissioning a dm-cache.
335
336 config DM_ERA
337        tristate "Era target (EXPERIMENTAL)"
338        depends on BLK_DEV_DM
339        default n
340        select DM_PERSISTENT_DATA
341        select DM_BIO_PRISON
342        ---help---
343          dm-era tracks which parts of a block device are written to
344          over time.  Useful for maintaining cache coherency when using
345          vendor snapshots.
346
347 config DM_MIRROR
348        tristate "Mirror target"
349        depends on BLK_DEV_DM
350        ---help---
351          Allow volume managers to mirror logical volumes, also
352          needed for live data migration tools such as 'pvmove'.
353
354 config DM_LOG_USERSPACE
355         tristate "Mirror userspace logging"
356         depends on DM_MIRROR && NET
357         select CONNECTOR
358         ---help---
359           The userspace logging module provides a mechanism for
360           relaying the dm-dirty-log API to userspace.  Log designs
361           which are more suited to userspace implementation (e.g.
362           shared storage logs) or experimental logs can be implemented
363           by leveraging this framework.
364
365 config DM_RAID
366        tristate "RAID 1/4/5/6/10 target"
367        depends on BLK_DEV_DM
368        select MD_RAID1
369        select MD_RAID10
370        select MD_RAID456
371        select BLK_DEV_MD
372        ---help---
373          A dm target that supports RAID1, RAID10, RAID4, RAID5 and RAID6 mappings
374
375          A RAID-5 set of N drives with a capacity of C MB per drive provides
376          the capacity of C * (N - 1) MB, and protects against a failure
377          of a single drive. For a given sector (row) number, (N - 1) drives
378          contain data sectors, and one drive contains the parity protection.
379          For a RAID-4 set, the parity blocks are present on a single drive,
380          while a RAID-5 set distributes the parity across the drives in one
381          of the available parity distribution methods.
382
383          A RAID-6 set of N drives with a capacity of C MB per drive
384          provides the capacity of C * (N - 2) MB, and protects
385          against a failure of any two drives. For a given sector
386          (row) number, (N - 2) drives contain data sectors, and two
387          drives contains two independent redundancy syndromes.  Like
388          RAID-5, RAID-6 distributes the syndromes across the drives
389          in one of the available parity distribution methods.
390
391 config DM_ZERO
392         tristate "Zero target"
393         depends on BLK_DEV_DM
394         ---help---
395           A target that discards writes, and returns all zeroes for
396           reads.  Useful in some recovery situations.
397
398 config DM_MULTIPATH
399         tristate "Multipath target"
400         depends on BLK_DEV_DM
401         # nasty syntax but means make DM_MULTIPATH independent
402         # of SCSI_DH if the latter isn't defined but if
403         # it is, DM_MULTIPATH must depend on it.  We get a build
404         # error if SCSI_DH=m and DM_MULTIPATH=y
405         depends on !SCSI_DH || SCSI
406         ---help---
407           Allow volume managers to support multipath hardware.
408
409 config DM_MULTIPATH_QL
410         tristate "I/O Path Selector based on the number of in-flight I/Os"
411         depends on DM_MULTIPATH
412         ---help---
413           This path selector is a dynamic load balancer which selects
414           the path with the least number of in-flight I/Os.
415
416           If unsure, say N.
417
418 config DM_MULTIPATH_ST
419         tristate "I/O Path Selector based on the service time"
420         depends on DM_MULTIPATH
421         ---help---
422           This path selector is a dynamic load balancer which selects
423           the path expected to complete the incoming I/O in the shortest
424           time.
425
426           If unsure, say N.
427
428 config DM_DELAY
429         tristate "I/O delaying target"
430         depends on BLK_DEV_DM
431         ---help---
432         A target that delays reads and/or writes and can send
433         them to different devices.  Useful for testing.
434
435         If unsure, say N.
436
437 config DM_UEVENT
438         bool "DM uevents"
439         depends on BLK_DEV_DM
440         ---help---
441         Generate udev events for DM events.
442
443 config DM_FLAKEY
444        tristate "Flakey target"
445        depends on BLK_DEV_DM
446        ---help---
447          A target that intermittently fails I/O for debugging purposes.
448
449 config DM_VERITY
450         tristate "Verity target support"
451         depends on BLK_DEV_DM
452         select CRYPTO
453         select CRYPTO_HASH
454         select DM_BUFIO
455         ---help---
456           This device-mapper target creates a read-only device that
457           transparently validates the data on one underlying device against
458           a pre-generated tree of cryptographic checksums stored on a second
459           device.
460
461           You'll need to activate the digests you're going to use in the
462           cryptoapi configuration.
463
464           To compile this code as a module, choose M here: the module will
465           be called dm-verity.
466
467           If unsure, say N.
468
469 config DM_VERITY_FEC
470         bool "Verity forward error correction support"
471         depends on DM_VERITY
472         select REED_SOLOMON
473         select REED_SOLOMON_DEC8
474         ---help---
475           Add forward error correction support to dm-verity. This option
476           makes it possible to use pre-generated error correction data to
477           recover from corrupted blocks.
478
479           If unsure, say N.
480
481 config DM_SWITCH
482         tristate "Switch target support (EXPERIMENTAL)"
483         depends on BLK_DEV_DM
484         ---help---
485           This device-mapper target creates a device that supports an arbitrary
486           mapping of fixed-size regions of I/O across a fixed set of paths.
487           The path used for any specific region can be switched dynamically
488           by sending the target a message.
489
490           To compile this code as a module, choose M here: the module will
491           be called dm-switch.
492
493           If unsure, say N.
494
495 config DM_LOG_WRITES
496         tristate "Log writes target support"
497         depends on BLK_DEV_DM
498         ---help---
499           This device-mapper target takes two devices, one device to use
500           normally, one to log all write operations done to the first device.
501           This is for use by file system developers wishing to verify that
502           their fs is writing a consistent file system at all times by allowing
503           them to replay the log in a variety of ways and to check the
504           contents.
505
506           To compile this code as a module, choose M here: the module will
507           be called dm-log-writes.
508
509           If unsure, say N.
510
511 endif # MD