Merge branches 'acpi-processor' and 'pnp'
[linux-2.6-block.git] / drivers / md / Kconfig
CommitLineData
1da177e4
LT
1#
2# Block device driver configuration
3#
4
afd44034 5menuconfig MD
1da177e4 6 bool "Multiple devices driver support (RAID and LVM)"
afd44034 7 depends on BLOCK
1da177e4
LT
8 help
9 Support multiple physical spindles through a single logical device.
10 Required for RAID and logical volume management.
11
afd44034
JE
12if MD
13
1da177e4
LT
14config BLK_DEV_MD
15 tristate "RAID support"
1da177e4
LT
16 ---help---
17 This driver lets you combine several hard disk partitions into one
18 logical block device. This can be used to simply append one
19 partition to another one or to combine several redundant hard disks
20 into a RAID1/4/5 device so as to provide protection against hard
21 disk failures. This is called "Software RAID" since the combining of
22 the partitions is done by the kernel. "Hardware RAID" means that the
23 combining is done by a dedicated controller; if you have such a
24 controller, you do not need to say Y here.
25
26 More information about Software RAID on Linux is contained in the
27 Software RAID mini-HOWTO, available from
28 <http://www.tldp.org/docs.html#howto>. There you will also learn
29 where to get the supporting user space utilities raidtools.
30
31 If unsure, say N.
32
a364092a
AV
33config MD_AUTODETECT
34 bool "Autodetect RAID arrays during kernel boot"
ce52aebd 35 depends on BLK_DEV_MD=y
a364092a
AV
36 default y
37 ---help---
38 If you say Y here, then the kernel will try to autodetect raid
39 arrays as part of its boot process.
40
41 If you don't use raid and say Y, this autodetection can cause
42 a several-second delay in the boot time due to various
43 synchronisation steps that are part of this step.
44
45 If unsure, say Y.
46
1da177e4
LT
47config MD_LINEAR
48 tristate "Linear (append) mode"
49 depends on BLK_DEV_MD
50 ---help---
51 If you say Y here, then your multiple devices driver will be able to
52 use the so-called linear mode, i.e. it will combine the hard disk
53 partitions by simply appending one to the other.
54
55 To compile this as a module, choose M here: the module
56 will be called linear.
57
58 If unsure, say Y.
59
60config MD_RAID0
61 tristate "RAID-0 (striping) mode"
62 depends on BLK_DEV_MD
63 ---help---
64 If you say Y here, then your multiple devices driver will be able to
65 use the so-called raid0 mode, i.e. it will combine the hard disk
66 partitions into one logical device in such a fashion as to fill them
67 up evenly, one chunk here and one chunk there. This will increase
68 the throughput rate if the partitions reside on distinct disks.
69
70 Information about Software RAID on Linux is contained in the
71 Software-RAID mini-HOWTO, available from
72 <http://www.tldp.org/docs.html#howto>. There you will also
73 learn where to get the supporting user space utilities raidtools.
74
75 To compile this as a module, choose M here: the module
76 will be called raid0.
77
78 If unsure, say Y.
79
80config MD_RAID1
81 tristate "RAID-1 (mirroring) mode"
82 depends on BLK_DEV_MD
83 ---help---
84 A RAID-1 set consists of several disk drives which are exact copies
85 of each other. In the event of a mirror failure, the RAID driver
86 will continue to use the operational mirrors in the set, providing
87 an error free MD (multiple device) to the higher levels of the
88 kernel. In a set with N drives, the available space is the capacity
89 of a single drive, and the set protects against a failure of (N - 1)
90 drives.
91
92 Information about Software RAID on Linux is contained in the
93 Software-RAID mini-HOWTO, available from
94 <http://www.tldp.org/docs.html#howto>. There you will also
95 learn where to get the supporting user space utilities raidtools.
96
97 If you want to use such a RAID-1 set, say Y. To compile this code
98 as a module, choose M here: the module will be called raid1.
99
100 If unsure, say Y.
101
102config MD_RAID10
08fb730c
N
103 tristate "RAID-10 (mirrored striping) mode"
104 depends on BLK_DEV_MD
1da177e4
LT
105 ---help---
106 RAID-10 provides a combination of striping (RAID-0) and
4d2554d0 107 mirroring (RAID-1) with easier configuration and more flexible
1da177e4
LT
108 layout.
109 Unlike RAID-0, but like RAID-1, RAID-10 requires all devices to
110 be the same size (or at least, only as much as the smallest device
111 will be used).
112 RAID-10 provides a variety of layouts that provide different levels
113 of redundancy and performance.
114
115 RAID-10 requires mdadm-1.7.0 or later, available at:
116
117 ftp://ftp.kernel.org/pub/linux/utils/raid/mdadm/
118
119 If unsure, say Y.
120
16a53ecc
N
121config MD_RAID456
122 tristate "RAID-4/RAID-5/RAID-6 mode"
1da177e4 123 depends on BLK_DEV_MD
f5e70d0f 124 select RAID6_PQ
9bc89cd8
DW
125 select ASYNC_MEMCPY
126 select ASYNC_XOR
ac6b53b6
DW
127 select ASYNC_PQ
128 select ASYNC_RAID6_RECOV
1da177e4
LT
129 ---help---
130 A RAID-5 set of N drives with a capacity of C MB per drive provides
131 the capacity of C * (N - 1) MB, and protects against a failure
132 of a single drive. For a given sector (row) number, (N - 1) drives
133 contain data sectors, and one drive contains the parity protection.
134 For a RAID-4 set, the parity blocks are present on a single drive,
135 while a RAID-5 set distributes the parity across the drives in one
136 of the available parity distribution methods.
137
16a53ecc
N
138 A RAID-6 set of N drives with a capacity of C MB per drive
139 provides the capacity of C * (N - 2) MB, and protects
140 against a failure of any two drives. For a given sector
141 (row) number, (N - 2) drives contain data sectors, and two
142 drives contains two independent redundancy syndromes. Like
143 RAID-5, RAID-6 distributes the syndromes across the drives
144 in one of the available parity distribution methods.
145
1da177e4
LT
146 Information about Software RAID on Linux is contained in the
147 Software-RAID mini-HOWTO, available from
148 <http://www.tldp.org/docs.html#howto>. There you will also
149 learn where to get the supporting user space utilities raidtools.
150
16a53ecc 151 If you want to use such a RAID-4/RAID-5/RAID-6 set, say Y. To
1da177e4 152 compile this code as a module, choose M here: the module
16a53ecc 153 will be called raid456.
1da177e4
LT
154
155 If unsure, say Y.
156
1da177e4
LT
157config MD_MULTIPATH
158 tristate "Multipath I/O support"
159 depends on BLK_DEV_MD
160 help
93bd89a6
N
161 MD_MULTIPATH provides a simple multi-path personality for use
162 the MD framework. It is not under active development. New
163 projects should consider using DM_MULTIPATH which has more
164 features and more testing.
1da177e4
LT
165
166 If unsure, say N.
167
168config MD_FAULTY
169 tristate "Faulty test module for MD"
170 depends on BLK_DEV_MD
171 help
172 The "faulty" module allows for a block device that occasionally returns
173 read or write errors. It is useful for testing.
174
175 In unsure, say N.
176
cafe5635
KO
177source "drivers/md/bcache/Kconfig"
178
2995fa78
MP
179config BLK_DEV_DM_BUILTIN
180 boolean
181
1da177e4
LT
182config BLK_DEV_DM
183 tristate "Device mapper support"
2995fa78 184 select BLK_DEV_DM_BUILTIN
1da177e4
LT
185 ---help---
186 Device-mapper is a low level volume manager. It works by allowing
187 people to specify mappings for ranges of logical sectors. Various
188 mapping types are available, in addition people may write their own
189 modules containing custom mappings if they wish.
190
191 Higher level volume managers such as LVM2 use this driver.
192
193 To compile this as a module, choose M here: the module will be
194 called dm-mod.
195
196 If unsure, say N.
197
cc109201
BR
198config DM_DEBUG
199 boolean "Device mapper debugging support"
0149e57f 200 depends on BLK_DEV_DM
cc109201
BR
201 ---help---
202 Enable this for messages that may help debug device-mapper problems.
203
204 If unsure, say N.
205
95d402f0
MP
206config DM_BUFIO
207 tristate
d57916a0 208 depends on BLK_DEV_DM
95d402f0
MP
209 ---help---
210 This interface allows you to do buffered I/O on a device and acts
211 as a cache, holding recently-read blocks in memory and performing
212 delayed writes.
213
4f81a417
MS
214config DM_BIO_PRISON
215 tristate
d57916a0 216 depends on BLK_DEV_DM
4f81a417
MS
217 ---help---
218 Some bio locking schemes used by other device-mapper targets
219 including thin provisioning.
220
991d9fa0
JT
221source "drivers/md/persistent-data/Kconfig"
222
1da177e4
LT
223config DM_CRYPT
224 tristate "Crypt target support"
0149e57f 225 depends on BLK_DEV_DM
1da177e4 226 select CRYPTO
3263263f 227 select CRYPTO_CBC
1da177e4
LT
228 ---help---
229 This device-mapper target allows you to create a device that
230 transparently encrypts the data on it. You'll need to activate
231 the ciphers you're going to use in the cryptoapi configuration.
232
233 Information on how to use dm-crypt can be found on
234
235 <http://www.saout.de/misc/dm-crypt/>
236
237 To compile this code as a module, choose M here: the module will
238 be called dm-crypt.
239
240 If unsure, say N.
241
242config DM_SNAPSHOT
0149e57f
AK
243 tristate "Snapshot target"
244 depends on BLK_DEV_DM
55494bf2 245 select DM_BUFIO
1da177e4 246 ---help---
4d2554d0 247 Allow volume managers to take writable snapshots of a device.
1da177e4 248
991d9fa0 249config DM_THIN_PROVISIONING
d57916a0
AK
250 tristate "Thin provisioning target"
251 depends on BLK_DEV_DM
991d9fa0 252 select DM_PERSISTENT_DATA
4f81a417 253 select DM_BIO_PRISON
991d9fa0
JT
254 ---help---
255 Provides thin provisioning and snapshots that share a data store.
256
c6b4fcba
JT
257config DM_CACHE
258 tristate "Cache target (EXPERIMENTAL)"
259 depends on BLK_DEV_DM
260 default n
261 select DM_PERSISTENT_DATA
262 select DM_BIO_PRISON
263 ---help---
264 dm-cache attempts to improve performance of a block device by
265 moving frequently used data to a smaller, higher performance
266 device. Different 'policy' plugins can be used to change the
267 algorithms used to select which blocks are promoted, demoted,
268 cleaned etc. It supports writeback and writethrough modes.
269
f2836352
JT
270config DM_CACHE_MQ
271 tristate "MQ Cache Policy (EXPERIMENTAL)"
272 depends on DM_CACHE
273 default y
274 ---help---
275 A cache policy that uses a multiqueue ordered by recent hit
276 count to select which blocks should be promoted and demoted.
277 This is meant to be a general purpose policy. It prioritises
278 reads over writes.
279
8735a813
HM
280config DM_CACHE_CLEANER
281 tristate "Cleaner Cache Policy (EXPERIMENTAL)"
282 depends on DM_CACHE
283 default y
284 ---help---
285 A simple cache policy that writes back all data to the
286 origin. Used when decommissioning a dm-cache.
287
1da177e4 288config DM_MIRROR
0149e57f
AK
289 tristate "Mirror target"
290 depends on BLK_DEV_DM
1da177e4
LT
291 ---help---
292 Allow volume managers to mirror logical volumes, also
293 needed for live data migration tools such as 'pvmove'.
294
5442851e
MP
295config DM_LOG_USERSPACE
296 tristate "Mirror userspace logging"
297 depends on DM_MIRROR && NET
298 select CONNECTOR
299 ---help---
300 The userspace logging module provides a mechanism for
301 relaying the dm-dirty-log API to userspace. Log designs
302 which are more suited to userspace implementation (e.g.
303 shared storage logs) or experimental logs can be implemented
304 by leveraging this framework.
305
9d09e663 306config DM_RAID
d9f691c3 307 tristate "RAID 1/4/5/6/10 target"
035220b3 308 depends on BLK_DEV_DM
b12d437b 309 select MD_RAID1
d9f691c3 310 select MD_RAID10
9d09e663
N
311 select MD_RAID456
312 select BLK_DEV_MD
313 ---help---
d9f691c3 314 A dm target that supports RAID1, RAID10, RAID4, RAID5 and RAID6 mappings
9d09e663
N
315
316 A RAID-5 set of N drives with a capacity of C MB per drive provides
317 the capacity of C * (N - 1) MB, and protects against a failure
318 of a single drive. For a given sector (row) number, (N - 1) drives
319 contain data sectors, and one drive contains the parity protection.
320 For a RAID-4 set, the parity blocks are present on a single drive,
321 while a RAID-5 set distributes the parity across the drives in one
322 of the available parity distribution methods.
323
324 A RAID-6 set of N drives with a capacity of C MB per drive
325 provides the capacity of C * (N - 2) MB, and protects
326 against a failure of any two drives. For a given sector
327 (row) number, (N - 2) drives contain data sectors, and two
328 drives contains two independent redundancy syndromes. Like
329 RAID-5, RAID-6 distributes the syndromes across the drives
330 in one of the available parity distribution methods.
331
1da177e4 332config DM_ZERO
0149e57f
AK
333 tristate "Zero target"
334 depends on BLK_DEV_DM
1da177e4
LT
335 ---help---
336 A target that discards writes, and returns all zeroes for
337 reads. Useful in some recovery situations.
338
339config DM_MULTIPATH
0149e57f
AK
340 tristate "Multipath target"
341 depends on BLK_DEV_DM
fe9233fb
CS
342 # nasty syntax but means make DM_MULTIPATH independent
343 # of SCSI_DH if the latter isn't defined but if
344 # it is, DM_MULTIPATH must depend on it. We get a build
345 # error if SCSI_DH=m and DM_MULTIPATH=y
346 depends on SCSI_DH || !SCSI_DH
1da177e4
LT
347 ---help---
348 Allow volume managers to support multipath hardware.
349
fd5e0339
KU
350config DM_MULTIPATH_QL
351 tristate "I/O Path Selector based on the number of in-flight I/Os"
352 depends on DM_MULTIPATH
353 ---help---
354 This path selector is a dynamic load balancer which selects
355 the path with the least number of in-flight I/Os.
356
357 If unsure, say N.
358
f392ba88
KU
359config DM_MULTIPATH_ST
360 tristate "I/O Path Selector based on the service time"
361 depends on DM_MULTIPATH
362 ---help---
363 This path selector is a dynamic load balancer which selects
364 the path expected to complete the incoming I/O in the shortest
365 time.
366
367 If unsure, say N.
368
26b9f228 369config DM_DELAY
d57916a0
AK
370 tristate "I/O delaying target"
371 depends on BLK_DEV_DM
26b9f228
HM
372 ---help---
373 A target that delays reads and/or writes and can send
374 them to different devices. Useful for testing.
375
376 If unsure, say N.
377
51e5b2bd 378config DM_UEVENT
e0b215da
AK
379 bool "DM uevents"
380 depends on BLK_DEV_DM
51e5b2bd
MA
381 ---help---
382 Generate udev events for DM events.
383
3407ef52 384config DM_FLAKEY
d57916a0
AK
385 tristate "Flakey target"
386 depends on BLK_DEV_DM
3407ef52
JB
387 ---help---
388 A target that intermittently fails I/O for debugging purposes.
389
a4ffc152 390config DM_VERITY
d57916a0
AK
391 tristate "Verity target support"
392 depends on BLK_DEV_DM
a4ffc152
MP
393 select CRYPTO
394 select CRYPTO_HASH
395 select DM_BUFIO
396 ---help---
397 This device-mapper target creates a read-only device that
398 transparently validates the data on one underlying device against
399 a pre-generated tree of cryptographic checksums stored on a second
400 device.
401
402 You'll need to activate the digests you're going to use in the
403 cryptoapi configuration.
404
405 To compile this code as a module, choose M here: the module will
406 be called dm-verity.
407
408 If unsure, say N.
409
9d0eb0ab
JR
410config DM_SWITCH
411 tristate "Switch target support (EXPERIMENTAL)"
412 depends on BLK_DEV_DM
413 ---help---
414 This device-mapper target creates a device that supports an arbitrary
415 mapping of fixed-size regions of I/O across a fixed set of paths.
416 The path used for any specific region can be switched dynamically
417 by sending the target a message.
418
419 To compile this code as a module, choose M here: the module will
420 be called dm-switch.
421
422 If unsure, say N.
423
afd44034 424endif # MD