Merge tag 'v4.5-rc1' into patchwork
[linux-2.6-block.git] / Documentation / thermal / sysfs-api.txt
CommitLineData
203d3d4a 1Generic Thermal Sysfs driver How To
38bb0849 2===================================
203d3d4a
ZR
3
4Written by Sujith Thomas <sujith.thomas@intel.com>, Zhang Rui <rui.zhang@intel.com>
5
6Updated: 2 January 2008
7
8Copyright (c) 2008 Intel Corporation
9
10
110. Introduction
12
38bb0849
FP
13The generic thermal sysfs provides a set of interfaces for thermal zone
14devices (sensors) and thermal cooling devices (fan, processor...) to register
15with the thermal management solution and to be a part of it.
203d3d4a 16
38bb0849
FP
17This how-to focuses on enabling new thermal zone and cooling devices to
18participate in thermal management.
19This solution is platform independent and any type of thermal zone devices
20and cooling devices should be able to make use of the infrastructure.
203d3d4a 21
38bb0849
FP
22The main task of the thermal sysfs driver is to expose thermal zone attributes
23as well as cooling device attributes to the user space.
24An intelligent thermal management application can make decisions based on
25inputs from thermal zone attributes (the current temperature and trip point
26temperature) and throttle appropriate devices.
203d3d4a
ZR
27
28[0-*] denotes any positive number starting from 0
29[1-*] denotes any positive number starting from 1
30
311. thermal sysfs driver interface functions
32
331.1 thermal zone device interface
514e6d20 341.1.1 struct thermal_zone_device *thermal_zone_device_register(char *type,
c56f5c03 35 int trips, int mask, void *devdata,
514e6d20
ZR
36 struct thermal_zone_device_ops *ops,
37 const struct thermal_zone_params *tzp,
38 int passive_delay, int polling_delay))
38bb0849
FP
39
40 This interface function adds a new thermal zone device (sensor) to
41 /sys/class/thermal folder as thermal_zone[0-*]. It tries to bind all the
42 thermal cooling devices registered at the same time.
43
514e6d20 44 type: the thermal zone type.
38bb0849 45 trips: the total number of trip points this thermal zone supports.
c56f5c03 46 mask: Bit string: If 'n'th bit is set, then trip point 'n' is writeable.
38bb0849
FP
47 devdata: device private data
48 ops: thermal zone device call-backs.
49 .bind: bind the thermal zone device with a thermal cooling device.
50 .unbind: unbind the thermal zone device with a thermal cooling device.
51 .get_temp: get the current temperature of the thermal zone.
8eaa8d6c
ZR
52 .get_mode: get the current mode (enabled/disabled) of the thermal zone.
53 - "enabled" means the kernel thermal management is enabled.
54 - "disabled" will prevent kernel thermal driver action upon trip points
38bb0849 55 so that user applications can take charge of thermal management.
8eaa8d6c 56 .set_mode: set the mode (enabled/disabled) of the thermal zone.
38bb0849
FP
57 .get_trip_type: get the type of certain trip point.
58 .get_trip_temp: get the temperature above which the certain trip point
59 will be fired.
e6e238c3
ADK
60 .set_emul_temp: set the emulation temperature which helps in debugging
61 different threshold temperature points.
514e6d20
ZR
62 tzp: thermal zone platform parameters.
63 passive_delay: number of milliseconds to wait between polls when
64 performing passive cooling.
65 polling_delay: number of milliseconds to wait between polls when checking
66 whether trip points have been crossed (0 for interrupt driven systems).
67
203d3d4a
ZR
68
691.1.2 void thermal_zone_device_unregister(struct thermal_zone_device *tz)
70
38bb0849
FP
71 This interface function removes the thermal zone device.
72 It deletes the corresponding entry form /sys/class/thermal folder and
73 unbind all the thermal cooling devices it uses.
203d3d4a
ZR
74
751.2 thermal cooling device interface
761.2.1 struct thermal_cooling_device *thermal_cooling_device_register(char *name,
38bb0849
FP
77 void *devdata, struct thermal_cooling_device_ops *)
78
79 This interface function adds a new thermal cooling device (fan/processor/...)
80 to /sys/class/thermal/ folder as cooling_device[0-*]. It tries to bind itself
81 to all the thermal zone devices register at the same time.
82 name: the cooling device name.
83 devdata: device private data.
84 ops: thermal cooling devices call-backs.
85 .get_max_state: get the Maximum throttle state of the cooling device.
86 .get_cur_state: get the Current throttle state of the cooling device.
87 .set_cur_state: set the Current throttle state of the cooling device.
203d3d4a
ZR
88
891.2.2 void thermal_cooling_device_unregister(struct thermal_cooling_device *cdev)
90
38bb0849
FP
91 This interface function remove the thermal cooling device.
92 It deletes the corresponding entry form /sys/class/thermal folder and
93 unbind itself from all the thermal zone devices using it.
203d3d4a
ZR
94
951.3 interface for binding a thermal zone device with a thermal cooling device
961.3.1 int thermal_zone_bind_cooling_device(struct thermal_zone_device *tz,
9d99842f 97 int trip, struct thermal_cooling_device *cdev,
6cd9e9f6 98 unsigned long upper, unsigned long lower, unsigned int weight);
203d3d4a 99
38bb0849
FP
100 This interface function bind a thermal cooling device to the certain trip
101 point of a thermal zone device.
102 This function is usually called in the thermal zone device .bind callback.
103 tz: the thermal zone device
104 cdev: thermal cooling device
105 trip: indicates which trip point the cooling devices is associated with
106 in this thermal zone.
9d99842f
ZR
107 upper:the Maximum cooling state for this trip point.
108 THERMAL_NO_LIMIT means no upper limit,
109 and the cooling device can be in max_state.
110 lower:the Minimum cooling state can be used for this trip point.
111 THERMAL_NO_LIMIT means no lower limit,
112 and the cooling device can be in cooling state 0.
6cd9e9f6
KS
113 weight: the influence of this cooling device in this thermal
114 zone. See 1.4.1 below for more information.
203d3d4a
ZR
115
1161.3.2 int thermal_zone_unbind_cooling_device(struct thermal_zone_device *tz,
38bb0849 117 int trip, struct thermal_cooling_device *cdev);
203d3d4a 118
38bb0849
FP
119 This interface function unbind a thermal cooling device from the certain
120 trip point of a thermal zone device. This function is usually called in
121 the thermal zone device .unbind callback.
122 tz: the thermal zone device
123 cdev: thermal cooling device
124 trip: indicates which trip point the cooling devices is associated with
125 in this thermal zone.
203d3d4a 126
6ea083b1
D
1271.4 Thermal Zone Parameters
1281.4.1 struct thermal_bind_params
129 This structure defines the following parameters that are used to bind
130 a zone with a cooling device for a particular trip point.
131 .cdev: The cooling device pointer
bcdcbbc7
JM
132 .weight: The 'influence' of a particular cooling device on this
133 zone. This is relative to the rest of the cooling
134 devices. For example, if all cooling devices have a
135 weight of 1, then they all contribute the same. You can
136 use percentages if you want, but it's not mandatory. A
137 weight of 0 means that this cooling device doesn't
138 contribute to the cooling of this zone unless all cooling
139 devices have a weight of 0. If all weights are 0, then
140 they all contribute the same.
6ea083b1
D
141 .trip_mask:This is a bit mask that gives the binding relation between
142 this thermal zone and cdev, for a particular trip point.
143 If nth bit is set, then the cdev and thermal zone are bound
144 for trip point n.
a8892d83
EV
145 .limits: This is an array of cooling state limits. Must have exactly
146 2 * thermal_zone.number_of_trip_points. It is an array consisting
147 of tuples <lower-state upper-state> of state limits. Each trip
148 will be associated with one state limit tuple when binding.
149 A NULL pointer means <THERMAL_NO_LIMITS THERMAL_NO_LIMITS>
150 on all trips. These limits are used when binding a cdev to a
151 trip point.
6ea083b1
D
152 .match: This call back returns success(0) if the 'tz and cdev' need to
153 be bound, as per platform data.
1541.4.2 struct thermal_zone_params
155 This structure defines the platform level parameters for a thermal zone.
156 This data, for each thermal zone should come from the platform layer.
157 This is an optional feature where some platforms can choose not to
158 provide this data.
159 .governor_name: Name of the thermal governor used for this zone
ccba4ffd
EV
160 .no_hwmon: a boolean to indicate if the thermal to hwmon sysfs interface
161 is required. when no_hwmon == false, a hwmon sysfs interface
162 will be created. when no_hwmon == true, nothing will be done.
163 In case the thermal_zone_params is NULL, the hwmon interface
164 will be created (for backward compatibility).
6ea083b1
D
165 .num_tbps: Number of thermal_bind_params entries for this zone
166 .tbp: thermal_bind_params entries
167
203d3d4a
ZR
1682. sysfs attributes structure
169
170RO read only value
171RW read/write value
172
e9ae7107
ZR
173Thermal sysfs attributes will be represented under /sys/class/thermal.
174Hwmon sysfs I/F extension is also available under /sys/class/hwmon
175if hwmon is compiled in or built as a module.
203d3d4a
ZR
176
177Thermal zone device sys I/F, created once it's registered:
e9ae7107 178/sys/class/thermal/thermal_zone[0-*]:
38bb0849
FP
179 |---type: Type of the thermal zone
180 |---temp: Current temperature
181 |---mode: Working mode of the thermal zone
6ea083b1 182 |---policy: Thermal governor used for this zone
25a0a5ce 183 |---available_policies: Available thermal governors for this zone
38bb0849
FP
184 |---trip_point_[0-*]_temp: Trip point temperature
185 |---trip_point_[0-*]_type: Trip point type
27365a6c 186 |---trip_point_[0-*]_hyst: Hysteresis value for this trip point
e6e238c3 187 |---emul_temp: Emulated temperature set node
9f38271c
JM
188 |---sustainable_power: Sustainable dissipatable power
189 |---k_po: Proportional term during temperature overshoot
190 |---k_pu: Proportional term during temperature undershoot
191 |---k_i: PID's integral term in the power allocator gov
192 |---k_d: PID's derivative term in the power allocator
193 |---integral_cutoff: Offset above which errors are accumulated
9d0be7f4
EV
194 |---slope: Slope constant applied as linear extrapolation
195 |---offset: Offset constant applied as linear extrapolation
203d3d4a
ZR
196
197Thermal cooling device sys I/F, created once it's registered:
e9ae7107 198/sys/class/thermal/cooling_device[0-*]:
38bb0849
FP
199 |---type: Type of the cooling device(processor/fan/...)
200 |---max_state: Maximum cooling state of the cooling device
201 |---cur_state: Current cooling state of the cooling device
203d3d4a
ZR
202
203
38bb0849
FP
204Then next two dynamic attributes are created/removed in pairs. They represent
205the relationship between a thermal zone and its associated cooling device.
206They are created/removed for each successful execution of
207thermal_zone_bind_cooling_device/thermal_zone_unbind_cooling_device.
203d3d4a 208
38bb0849
FP
209/sys/class/thermal/thermal_zone[0-*]:
210 |---cdev[0-*]: [0-*]th cooling device in current thermal zone
211 |---cdev[0-*]_trip_point: Trip point that cdev[0-*] is associated with
db916513
JM
212 |---cdev[0-*]_weight: Influence of the cooling device in
213 this thermal zone
203d3d4a 214
e9ae7107 215Besides the thermal zone device sysfs I/F and cooling device sysfs I/F,
38bb0849
FP
216the generic thermal driver also creates a hwmon sysfs I/F for each _type_
217of thermal zone device. E.g. the generic thermal driver registers one hwmon
218class device and build the associated hwmon sysfs I/F for all the registered
219ACPI thermal zones.
220
e9ae7107 221/sys/class/hwmon/hwmon[0-*]:
38bb0849
FP
222 |---name: The type of the thermal zone devices
223 |---temp[1-*]_input: The current temperature of thermal zone [1-*]
224 |---temp[1-*]_critical: The critical trip point of thermal zone [1-*]
225
e9ae7107 226Please read Documentation/hwmon/sysfs-interface for additional information.
203d3d4a
ZR
227
228***************************
229* Thermal zone attributes *
230***************************
231
38bb0849
FP
232type
233 Strings which represent the thermal zone type.
234 This is given by thermal zone driver as part of registration.
235 E.g: "acpitz" indicates it's an ACPI thermal device.
236 In order to keep it consistent with hwmon sys attribute; this should
237 be a short, lowercase string, not containing spaces nor dashes.
238 RO, Required
239
240temp
241 Current temperature as reported by thermal zone (sensor).
242 Unit: millidegree Celsius
243 RO, Required
244
245mode
8eaa8d6c 246 One of the predefined values in [enabled, disabled].
38bb0849
FP
247 This file gives information about the algorithm that is currently
248 managing the thermal zone. It can be either default kernel based
249 algorithm or user space application.
8eaa8d6c
ZR
250 enabled = enable Kernel Thermal management.
251 disabled = Preventing kernel thermal zone driver actions upon
252 trip points so that user application can take full
253 charge of the thermal management.
38bb0849
FP
254 RW, Optional
255
6ea083b1
D
256policy
257 One of the various thermal governors used for a particular zone.
258 RW, Required
259
25a0a5ce
NW
260available_policies
261 Available thermal governors which can be used for a particular zone.
262 RO, Required
263
38bb0849
FP
264trip_point_[0-*]_temp
265 The temperature above which trip point will be fired.
266 Unit: millidegree Celsius
267 RO, Optional
268
269trip_point_[0-*]_type
270 Strings which indicate the type of the trip point.
271 E.g. it can be one of critical, hot, passive, active[0-*] for ACPI
272 thermal zone.
273 RO, Optional
274
27365a6c
D
275trip_point_[0-*]_hyst
276 The hysteresis value for a trip point, represented as an integer
277 Unit: Celsius
278 RW, Optional
279
38bb0849
FP
280cdev[0-*]
281 Sysfs link to the thermal cooling device node where the sys I/F
282 for cooling device throttling control represents.
283 RO, Optional
284
285cdev[0-*]_trip_point
286 The trip point with which cdev[0-*] is associated in this thermal
287 zone; -1 means the cooling device is not associated with any trip
288 point.
289 RO, Optional
29226ed3 290
db916513
JM
291cdev[0-*]_weight
292 The influence of cdev[0-*] in this thermal zone. This value
293 is relative to the rest of cooling devices in the thermal
294 zone. For example, if a cooling device has a weight double
295 than that of other, it's twice as effective in cooling the
296 thermal zone.
297 RW, Optional
298
29226ed3
FP
299passive
300 Attribute is only present for zones in which the passive cooling
301 policy is not supported by native thermal driver. Default is zero
302 and can be set to a temperature (in millidegrees) to enable a
303 passive trip point for the zone. Activation is done by polling with
304 an interval of 1 second.
305 Unit: millidegrees Celsius
3d8e3ad8 306 Valid values: 0 (disabled) or greater than 1000
29226ed3 307 RW, Optional
38bb0849 308
e6e238c3
ADK
309emul_temp
310 Interface to set the emulated temperature method in thermal zone
311 (sensor). After setting this temperature, the thermal zone may pass
312 this temperature to platform emulation function if registered or
313 cache it locally. This is useful in debugging different temperature
314 threshold and its associated cooling action. This is write only node
315 and writing 0 on this node should disable emulation.
316 Unit: millidegree Celsius
317 WO, Optional
318
8837295a
EV
319 WARNING: Be careful while enabling this option on production systems,
320 because userland can easily disable the thermal policy by simply
321 flooding this sysfs node with low temperature values.
322
9f38271c
JM
323sustainable_power
324 An estimate of the sustained power that can be dissipated by
325 the thermal zone. Used by the power allocator governor. For
326 more information see Documentation/thermal/power_allocator.txt
327 Unit: milliwatts
328 RW, Optional
329
330k_po
331 The proportional term of the power allocator governor's PID
332 controller during temperature overshoot. Temperature overshoot
333 is when the current temperature is above the "desired
334 temperature" trip point. For more information see
335 Documentation/thermal/power_allocator.txt
336 RW, Optional
337
338k_pu
339 The proportional term of the power allocator governor's PID
340 controller during temperature undershoot. Temperature undershoot
341 is when the current temperature is below the "desired
342 temperature" trip point. For more information see
343 Documentation/thermal/power_allocator.txt
344 RW, Optional
345
346k_i
347 The integral term of the power allocator governor's PID
348 controller. This term allows the PID controller to compensate
349 for long term drift. For more information see
350 Documentation/thermal/power_allocator.txt
351 RW, Optional
352
353k_d
354 The derivative term of the power allocator governor's PID
355 controller. For more information see
356 Documentation/thermal/power_allocator.txt
357 RW, Optional
358
359integral_cutoff
360 Temperature offset from the desired temperature trip point
361 above which the integral term of the power allocator
362 governor's PID controller starts accumulating errors. For
363 example, if integral_cutoff is 0, then the integral term only
364 accumulates error when temperature is above the desired
365 temperature trip point. For more information see
366 Documentation/thermal/power_allocator.txt
ec3fc58b 367 Unit: millidegree Celsius
9f38271c
JM
368 RW, Optional
369
9d0be7f4
EV
370slope
371 The slope constant used in a linear extrapolation model
372 to determine a hotspot temperature based off the sensor's
373 raw readings. It is up to the device driver to determine
374 the usage of these values.
375 RW, Optional
376
377offset
378 The offset constant used in a linear extrapolation model
379 to determine a hotspot temperature based off the sensor's
380 raw readings. It is up to the device driver to determine
381 the usage of these values.
382 RW, Optional
383
38bb0849
FP
384*****************************
385* Cooling device attributes *
386*****************************
387
388type
389 String which represents the type of device, e.g:
390 - for generic ACPI: should be "Fan", "Processor" or "LCD"
391 - for memory controller device on intel_menlow platform:
392 should be "Memory controller".
393 RO, Required
394
395max_state
396 The maximum permissible cooling state of this cooling device.
397 RO, Required
398
399cur_state
400 The current cooling state of this cooling device.
401 The value can any integer numbers between 0 and max_state:
402 - cur_state == 0 means no cooling
403 - cur_state == max_state means the maximum cooling.
404 RW, Required
203d3d4a
ZR
405
4063. A simple implementation
407
38bb0849
FP
408ACPI thermal zone may support multiple trip points like critical, hot,
409passive, active. If an ACPI thermal zone supports critical, passive,
410active[0] and active[1] at the same time, it may register itself as a
411thermal_zone_device (thermal_zone1) with 4 trip points in all.
412It has one processor and one fan, which are both registered as
db916513
JM
413thermal_cooling_device. Both are considered to have the same
414effectiveness in cooling the thermal zone.
38bb0849
FP
415
416If the processor is listed in _PSL method, and the fan is listed in _AL0
417method, the sys I/F structure will be built like this:
203d3d4a
ZR
418
419/sys/class/thermal:
420
421|thermal_zone1:
38bb0849
FP
422 |---type: acpitz
423 |---temp: 37000
8eaa8d6c 424 |---mode: enabled
6ea083b1 425 |---policy: step_wise
25a0a5ce 426 |---available_policies: step_wise fair_share
38bb0849
FP
427 |---trip_point_0_temp: 100000
428 |---trip_point_0_type: critical
429 |---trip_point_1_temp: 80000
430 |---trip_point_1_type: passive
431 |---trip_point_2_temp: 70000
432 |---trip_point_2_type: active0
433 |---trip_point_3_temp: 60000
434 |---trip_point_3_type: active1
435 |---cdev0: --->/sys/class/thermal/cooling_device0
436 |---cdev0_trip_point: 1 /* cdev0 can be used for passive */
db916513 437 |---cdev0_weight: 1024
38bb0849
FP
438 |---cdev1: --->/sys/class/thermal/cooling_device3
439 |---cdev1_trip_point: 2 /* cdev1 can be used for active[0]*/
db916513 440 |---cdev1_weight: 1024
203d3d4a
ZR
441
442|cooling_device0:
38bb0849
FP
443 |---type: Processor
444 |---max_state: 8
445 |---cur_state: 0
203d3d4a
ZR
446
447|cooling_device3:
38bb0849
FP
448 |---type: Fan
449 |---max_state: 2
450 |---cur_state: 0
e9ae7107
ZR
451
452/sys/class/hwmon:
453
454|hwmon0:
38bb0849
FP
455 |---name: acpitz
456 |---temp1_input: 37000
457 |---temp1_crit: 100000
4cb18728
D
458
4594. Event Notification
460
461The framework includes a simple notification mechanism, in the form of a
462netlink event. Netlink socket initialization is done during the _init_
463of the framework. Drivers which intend to use the notification mechanism
2d58d7ea 464just need to call thermal_generate_netlink_event() with two arguments viz
8ab3e6a0
EV
465(originator, event). The originator is a pointer to struct thermal_zone_device
466from where the event has been originated. An integer which represents the
467thermal zone device will be used in the message to identify the zone. The
4cb18728
D
468event will be one of:{THERMAL_AUX0, THERMAL_AUX1, THERMAL_CRITICAL,
469THERMAL_DEV_FAULT}. Notification can be sent when the current temperature
470crosses any of the configured thresholds.
6ea083b1
D
471
4725. Export Symbol APIs:
473
4745.1: get_tz_trend:
475This function returns the trend of a thermal zone, i.e the rate of change
476of temperature of the thermal zone. Ideally, the thermal sensor drivers
477are supposed to implement the callback. If they don't, the thermal
478framework calculated the trend by comparing the previous and the current
479temperature values.
480
4815.2:get_thermal_instance:
482This function returns the thermal_instance corresponding to a given
483{thermal_zone, cooling_device, trip_point} combination. Returns NULL
484if such an instance does not exist.
485
7b73c993 4865.3:thermal_notify_framework:
6ea083b1
D
487This function handles the trip events from sensor drivers. It starts
488throttling the cooling devices according to the policy configured.
489For CRITICAL and HOT trip points, this notifies the respective drivers,
490and does actual throttling for other trip points i.e ACTIVE and PASSIVE.
491The throttling policy is based on the configured platform data; if no
492platform data is provided, this uses the step_wise throttling policy.
493
4945.4:thermal_cdev_update:
495This function serves as an arbitrator to set the state of a cooling
496device. It sets the cooling device to the deepest cooling state if
497possible.