IB/mlx4: Utilize macro to calculate SQ spare size
[linux-2.6-block.git] / Documentation / hwmon / ibmpowernv
CommitLineData
24c1aa85
NG
1Kernel Driver IBMPOWERNV
2========================
3
4Supported systems:
5 * Any recent IBM P servers based on POWERNV platform
6
7Author: Neelesh Gupta
8
9Description
10-----------
11
12This driver implements reading the platform sensors data like temperature/fan/
13voltage/power for 'POWERNV' platform.
14
15The driver uses the platform device infrastructure. It probes the device tree
16for sensor devices during the __init phase and registers them with the 'hwmon'.
17'hwmon' populates the 'sysfs' tree having attribute files, each for a given
18sensor type and its attribute data.
19
20All the nodes in the DT appear under "/ibm,opal/sensors" and each valid node in
21the DT maps to an attribute file in 'sysfs'. The node exports unique 'sensor-id'
22which the driver uses to make an OPAL call to the firmware.
23
24Usage notes
25-----------
26The driver is built statically with the kernel by enabling the config
27CONFIG_SENSORS_IBMPOWERNV. It can also be built as module 'ibmpowernv'.
28
29Sysfs attributes
30----------------
31
32fanX_input Measured RPM value.
33fanX_min Threshold RPM for alert generation.
34fanX_fault 0: No fail condition
35 1: Failing fan
e0da9912 36
24c1aa85
NG
37tempX_input Measured ambient temperature.
38tempX_max Threshold ambient temperature for alert generation.
e0da9912
SB
39tempX_highest Historical maximum temperature
40tempX_lowest Historical minimum temperature
41tempX_enable Enable/disable all temperature sensors belonging to the
42 sub-group. In POWER9, this attribute corresponds to
43 each OCC. Using this attribute each OCC can be asked to
44 disable/enable all of its temperature sensors.
45 1: Enable
46 0: Disable
47
48inX_input Measured power supply voltage (millivolt)
24c1aa85
NG
49inX_fault 0: No fail condition.
50 1: Failing power supply.
e0da9912
SB
51inX_highest Historical maximum voltage
52inX_lowest Historical minimum voltage
53inX_enable Enable/disable all voltage sensors belonging to the
54 sub-group. In POWER9, this attribute corresponds to
55 each OCC. Using this attribute each OCC can be asked to
56 disable/enable all of its voltage sensors.
57 1: Enable
58 0: Disable
59
60powerX_input Power consumption (microWatt)
61powerX_input_highest Historical maximum power
62powerX_input_lowest Historical minimum power
63powerX_enable Enable/disable all power sensors belonging to the
64 sub-group. In POWER9, this attribute corresponds to
65 each OCC. Using this attribute each OCC can be asked to
66 disable/enable all of its power sensors.
67 1: Enable
68 0: Disable
69
70currX_input Measured current (milliampere)
71currX_highest Historical maximum current
72currX_lowest Historical minimum current
73currX_enable Enable/disable all current sensors belonging to the
74 sub-group. In POWER9, this attribute corresponds to
75 each OCC. Using this attribute each OCC can be asked to
76 disable/enable all of its current sensors.
77 1: Enable
78 0: Disable
79
80energyX_input Cumulative energy (microJoule)