Commit | Line | Data |
---|---|---|
83f7649c GR |
1 | Kernel driver adm1275 |
2 | ===================== | |
3 | ||
4 | Supported chips: | |
5 | * Analog Devices ADM1275 | |
6 | Prefix: 'adm1275' | |
7 | Addresses scanned: - | |
8 | Datasheet: www.analog.com/static/imported-files/data_sheets/ADM1275.pdf | |
9 | ||
10 | Author: Guenter Roeck <guenter.roeck@ericsson.com> | |
11 | ||
12 | ||
13 | Description | |
14 | ----------- | |
15 | ||
16 | This driver supports hardware montoring for Analog Devices ADM1275 Hot-Swap | |
17 | Controller and Digital Power Monitor. | |
18 | ||
19 | The ADM1275 is a hot-swap controller that allows a circuit board to be removed | |
20 | from or inserted into a live backplane. It also features current and voltage | |
21 | readback via an integrated 12-bit analog-to-digital converter (ADC), accessed | |
22 | using a PMBus. interface. | |
23 | ||
24 | The driver is a client driver to the core PMBus driver. Please see | |
25 | Documentation/hwmon/pmbus for details on PMBus client drivers. | |
26 | ||
27 | ||
28 | Usage Notes | |
29 | ----------- | |
30 | ||
31 | This driver does not auto-detect devices. You will have to instantiate the | |
32 | devices explicitly. Please see Documentation/i2c/instantiating-devices for | |
33 | details. | |
34 | ||
35 | ||
36 | Platform data support | |
37 | --------------------- | |
38 | ||
39 | The driver supports standard PMBus driver platform data. Please see | |
40 | Documentation/hwmon/pmbus for details. | |
41 | ||
42 | ||
43 | Sysfs entries | |
44 | ------------- | |
45 | ||
46 | The following attributes are supported. Limits are read-write; all other | |
47 | attributes are read-only. | |
48 | ||
49 | in1_label "vin1" or "vout1" depending on chip variant and | |
50 | configuration. | |
51 | in1_input Measured voltage. From READ_VOUT register. | |
52 | in1_min Minumum Voltage. From VOUT_UV_WARN_LIMIT register. | |
53 | in1_max Maximum voltage. From VOUT_OV_WARN_LIMIT register. | |
54 | in1_min_alarm Voltage low alarm. From VOLTAGE_UV_WARNING status. | |
55 | in1_max_alarm Voltage high alarm. From VOLTAGE_OV_WARNING status. | |
56 | ||
57 | curr1_label "iout1" | |
58 | curr1_input Measured current. From READ_IOUT register. | |
59 | curr1_max Maximum current. From IOUT_OC_WARN_LIMIT register. | |
60 | curr1_max_alarm Current high alarm. From IOUT_OC_WARN_LIMIT register. |