Commit | Line | Data |
---|---|---|
7effa5b0 MCC |
1 | =================================== |
2 | Dell Systems Management Base Driver | |
3 | =================================== | |
4 | ||
90563ec4 | 5 | Overview |
7effa5b0 | 6 | ======== |
90563ec4 DW |
7 | |
8 | The Dell Systems Management Base Driver provides a sysfs interface for | |
9 | systems management software such as Dell OpenManage to perform system | |
10 | management interrupts and host control actions (system power cycle or | |
11 | power off after OS shutdown) on certain Dell systems. | |
12 | ||
13 | Dell OpenManage requires this driver on the following Dell PowerEdge systems: | |
14 | 300, 1300, 1400, 400SC, 500SC, 1500SC, 1550, 600SC, 1600SC, 650, 1655MC, | |
15 | 700, and 750. Other Dell software such as the open source libsmbios project | |
16 | is expected to make use of this driver, and it may include the use of this | |
17 | driver on other Dell systems. | |
18 | ||
19 | The Dell libsmbios project aims towards providing access to as much BIOS | |
20 | information as possible. See http://linux.dell.com/libsmbios/main/ for | |
21 | more information about the libsmbios project. | |
22 | ||
23 | ||
24 | System Management Interrupt | |
7effa5b0 | 25 | =========================== |
90563ec4 DW |
26 | |
27 | On some Dell systems, systems management software must access certain | |
28 | management information via a system management interrupt (SMI). The SMI data | |
29 | buffer must reside in 32-bit address space, and the physical address of the | |
30 | buffer is required for the SMI. The driver maintains the memory required for | |
31 | the SMI and provides a way for the application to generate the SMI. | |
32 | The driver creates the following sysfs entries for systems management | |
7effa5b0 | 33 | software to perform these system management interrupts:: |
90563ec4 | 34 | |
7effa5b0 MCC |
35 | /sys/devices/platform/dcdbas/smi_data |
36 | /sys/devices/platform/dcdbas/smi_data_buf_phys_addr | |
37 | /sys/devices/platform/dcdbas/smi_data_buf_size | |
38 | /sys/devices/platform/dcdbas/smi_request | |
90563ec4 DW |
39 | |
40 | Systems management software must perform the following steps to execute | |
41 | a SMI using this driver: | |
42 | ||
43 | 1) Lock smi_data. | |
44 | 2) Write system management command to smi_data. | |
45 | 3) Write "1" to smi_request to generate a calling interface SMI or | |
46 | "2" to generate a raw SMI. | |
47 | 4) Read system management command response from smi_data. | |
48 | 5) Unlock smi_data. | |
49 | ||
50 | ||
51 | Host Control Action | |
7effa5b0 | 52 | =================== |
90563ec4 DW |
53 | |
54 | Dell OpenManage supports a host control feature that allows the administrator | |
55 | to perform a power cycle or power off of the system after the OS has finished | |
56 | shutting down. On some Dell systems, this host control feature requires that | |
57 | a driver perform a SMI after the OS has finished shutting down. | |
58 | ||
59 | The driver creates the following sysfs entries for systems management software | |
60 | to schedule the driver to perform a power cycle or power off host control | |
61 | action after the system has finished shutting down: | |
62 | ||
63 | /sys/devices/platform/dcdbas/host_control_action | |
64 | /sys/devices/platform/dcdbas/host_control_smi_type | |
65 | /sys/devices/platform/dcdbas/host_control_on_shutdown | |
66 | ||
67 | Dell OpenManage performs the following steps to execute a power cycle or | |
68 | power off host control action using this driver: | |
69 | ||
70 | 1) Write host control action to be performed to host_control_action. | |
71 | 2) Write type of SMI that driver needs to perform to host_control_smi_type. | |
72 | 3) Write "1" to host_control_on_shutdown to enable host control action. | |
73 | 4) Initiate OS shutdown. | |
74 | (Driver will perform host control SMI when it is notified that the OS | |
75 | has finished shutting down.) | |
76 | ||
77 | ||
78 | Host Control SMI Type | |
7effa5b0 | 79 | ===================== |
90563ec4 DW |
80 | |
81 | The following table shows the value to write to host_control_smi_type to | |
82 | perform a power cycle or power off host control action: | |
83 | ||
7effa5b0 | 84 | =================== ===================== |
90563ec4 | 85 | PowerEdge System Host Control SMI Type |
7effa5b0 | 86 | =================== ===================== |
90563ec4 DW |
87 | 300 HC_SMITYPE_TYPE1 |
88 | 1300 HC_SMITYPE_TYPE1 | |
89 | 1400 HC_SMITYPE_TYPE2 | |
90 | 500SC HC_SMITYPE_TYPE2 | |
91 | 1500SC HC_SMITYPE_TYPE2 | |
92 | 1550 HC_SMITYPE_TYPE2 | |
93 | 600SC HC_SMITYPE_TYPE2 | |
94 | 1600SC HC_SMITYPE_TYPE2 | |
95 | 650 HC_SMITYPE_TYPE2 | |
96 | 1655MC HC_SMITYPE_TYPE2 | |
97 | 700 HC_SMITYPE_TYPE3 | |
98 | 750 HC_SMITYPE_TYPE3 | |
7effa5b0 | 99 | =================== ===================== |