Commit | Line | Data |
---|---|---|
b73b93a2 MC |
1 | What: /sys/bus/iio/devices/iio:deviceX/ac_excitation_en |
2 | KernelVersion: | |
3 | Contact: linux-iio@vger.kernel.org | |
4 | Description: | |
7e4d7593 AT |
5 | This attribute, if available, is used to enable the AC |
6 | excitation mode found on some converters. In ac excitation mode, | |
7 | the polarity of the excitation voltage is reversed on | |
8 | alternate cycles, to eliminate DC errors. | |
b73b93a2 MC |
9 | |
10 | What: /sys/bus/iio/devices/iio:deviceX/bridge_switch_en | |
11 | KernelVersion: | |
12 | Contact: linux-iio@vger.kernel.org | |
13 | Description: | |
7e4d7593 AT |
14 | This attribute, if available, is used to close or open the |
15 | bridge power down switch found on some converters. | |
16 | In bridge applications, such as strain gauges and load cells, | |
17 | the bridge itself consumes the majority of the current in the | |
18 | system. To minimize the current consumption of the system, | |
19 | the bridge can be disconnected (when it is not being used | |
20 | using the bridge_switch_en attribute. | |
42776c14 MC |
21 | |
22 | What: /sys/bus/iio/devices/iio:deviceX/in_voltagex_sys_calibration | |
23 | KernelVersion: | |
24 | Contact: linux-iio@vger.kernel.org | |
25 | Description: | |
26 | Initiates the system calibration procedure. This is done on a | |
27 | single channel at a time. Write '1' to start the calibration. | |
28 | ||
7e4d7593 AT |
29 | What: /sys/bus/iio/devices/iio:deviceX/in_voltage2-voltage2_shorted_raw |
30 | KernelVersion: | |
31 | Contact: linux-iio@vger.kernel.org | |
32 | Description: | |
33 | Measure voltage from AIN2 pin connected to AIN(+) | |
34 | and AIN(-) shorted. | |
35 | ||
42776c14 MC |
36 | What: /sys/bus/iio/devices/iio:deviceX/in_voltagex_sys_calibration_mode_available |
37 | KernelVersion: | |
38 | Contact: linux-iio@vger.kernel.org | |
39 | Description: | |
40 | Reading returns a list with the possible calibration modes. | |
41 | There are two available options: | |
42 | "zero_scale" - calibrate to zero scale | |
43 | "full_scale" - calibrate to full scale | |
44 | ||
45 | What: /sys/bus/iio/devices/iio:deviceX/in_voltagex_sys_calibration_mode | |
46 | KernelVersion: | |
47 | Contact: linux-iio@vger.kernel.org | |
48 | Description: | |
49 | Sets up the calibration mode used in the system calibration | |
50 | procedure. Reading returns the current calibration mode. | |
51 | Writing sets the system calibration mode. |