docs: hwmon: ibmpowernv: convert to ReST format
authorMauro Carvalho Chehab <mchehab+samsung@kernel.org>
Wed, 17 Apr 2019 09:46:19 +0000 (06:46 -0300)
committerGuenter Roeck <linux@roeck-us.net>
Wed, 17 Apr 2019 16:51:03 +0000 (09:51 -0700)
Convert ibmpowernv to ReST format, in order to allow it to
be parsed by Sphinx.

Signed-off-by: Mauro Carvalho Chehab <mchehab+samsung@kernel.org>
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
Documentation/hwmon/ibmpowernv

index 56468258711f1b36a5b7c74612003df9df2de694..5d642bc3dec0f8febf62a9eeee2f18fc22e45321 100644 (file)
@@ -2,6 +2,7 @@ Kernel Driver IBMPOWERNV
 ========================
 
 Supported systems:
+
   * Any recent IBM P servers based on POWERNV platform
 
 Author: Neelesh Gupta
@@ -29,10 +30,11 @@ CONFIG_SENSORS_IBMPOWERNV. It can also be built as module 'ibmpowernv'.
 Sysfs attributes
 ----------------
 
+======================= =======================================================
 fanX_input             Measured RPM value.
 fanX_min               Threshold RPM for alert generation.
-fanX_fault             0: No fail condition
-                       1: Failing fan
+fanX_fault             0: No fail condition
+                       1: Failing fan
 
 tempX_input            Measured ambient temperature.
 tempX_max              Threshold ambient temperature for alert generation.
@@ -42,20 +44,22 @@ tempX_enable                Enable/disable all temperature sensors belonging to the
                        sub-group. In POWER9, this attribute corresponds to
                        each OCC. Using this attribute each OCC can be asked to
                        disable/enable all of its temperature sensors.
-                       1: Enable
-                       0: Disable
+
+                       - 1: Enable
+                       - 0: Disable
 
 inX_input              Measured power supply voltage (millivolt)
-inX_fault              0: No fail condition.
-                       1: Failing power supply.
+inX_fault              0: No fail condition.
+                       1: Failing power supply.
 inX_highest            Historical maximum voltage
 inX_lowest             Historical minimum voltage
 inX_enable             Enable/disable all voltage sensors belonging to the
                        sub-group. In POWER9, this attribute corresponds to
                        each OCC. Using this attribute each OCC can be asked to
                        disable/enable all of its voltage sensors.
-                       1: Enable
-                       0: Disable
+
+                       - 1: Enable
+                       - 0: Disable
 
 powerX_input           Power consumption (microWatt)
 powerX_input_highest   Historical maximum power
@@ -64,8 +68,9 @@ powerX_enable         Enable/disable all power sensors belonging to the
                        sub-group. In POWER9, this attribute corresponds to
                        each OCC. Using this attribute each OCC can be asked to
                        disable/enable all of its power sensors.
-                       1: Enable
-                       0: Disable
+
+                       - 1: Enable
+                       - 0: Disable
 
 currX_input            Measured current (milliampere)
 currX_highest          Historical maximum current
@@ -74,7 +79,9 @@ currX_enable          Enable/disable all current sensors belonging to the
                        sub-group. In POWER9, this attribute corresponds to
                        each OCC. Using this attribute each OCC can be asked to
                        disable/enable all of its current sensors.
-                       1: Enable
-                       0: Disable
+
+                       - 1: Enable
+                       - 0: Disable
 
 energyX_input          Cumulative energy (microJoule)
+======================= =======================================================