media: cec: keep track of outstanding transmits
authorHans Verkuil <hverkuil-cisco@xs4all.nl>
Fri, 19 Oct 2018 07:55:34 +0000 (03:55 -0400)
committerMauro Carvalho Chehab <mchehab+samsung@kernel.org>
Fri, 23 Nov 2018 10:56:14 +0000 (05:56 -0500)
commit32804fcb612bf867034a093f459415e485cf044b
tree262dcb0b582428b81508ad14a81fa136c3f88c60
parentdb07c5ca5596901a9723245c0068668a7f2403c6
media: cec: keep track of outstanding transmits

I noticed that repeatedly running 'cec-ctl --playback' would occasionally
select 'Playback Device 2' instead of 'Playback Device 1', even though there
were no other Playback devices in the HDMI topology. This happened both with
'real' hardware and with the vivid CEC emulation, suggesting that this was an
issue in the core code that claims a logical address.

What 'cec-ctl --playback' does is to first clear all existing logical addresses,
and immediately after that configure the new desired device type.

The core code will poll the logical addresses trying to find a free address.
When found it will issue a few standard messages as per the CEC spec and return.
Those messages are queued up and will be transmitted asynchronously.

What happens is that if you run two 'cec-ctl --playback' commands in quick
succession, there is still a message of the first cec-ctl command being transmitted
when you reconfigure the adapter again in the second cec-ctl command.

When the logical addresses are cleared, then all information about outstanding
transmits inside the CEC core is also cleared, and the core is no longer aware
that there is still a transmit in flight.

When the hardware finishes the transmit it calls transmit_done and the CEC core
thinks it is actually in response of a POLL messages that is trying to find a
free logical address. The result of all this is that the core thinks that the
logical address for Playback Device 1 is in use, when it is really an earlier
transmit that ended.

The main transmit thread looks at adap->transmitting to check if a transmit
is in progress, but that is set to NULL when the adapter is unconfigured.
adap->transmitting represents the view of userspace, not that of the hardware.
So when unconfiguring the adapter the message is marked aborted from the point
of view of userspace, but seen from the PoV of the hardware it is still ongoing.

So introduce a new bool transmit_in_progress that represents the hardware state
and use that instead of adap->transmitting. Now the CEC core waits until the
hardware finishes the transmit before starting a new transmit.

Signed-off-by: Hans Verkuil <hverkuil-cisco@xs4all.nl>
Cc: <stable@vger.kernel.org> # for v4.18 and up
Signed-off-by: Mauro Carvalho Chehab <mchehab+samsung@kernel.org>
drivers/media/cec/cec-adap.c
include/media/cec.h